2. IMPORTANT INFORMATION ABOUT SAFETY! PLEASE READ THESE IN-
STRUCTIONS AND KEEP THEM.

•  Do not remove or disconnect the communication module battery to mute a false alarm. In this 

case, the detector will lose its alarming features. Ventilate the area around the detector to mute 

the detector or press and hold the test button for 3 seconds.

•  The test button thoroughly checks all features of the smoke detector. Do not use any other test 

method. Test the smoke detector to ensure proper operation.

•  If you need help installing the smoke detector, contact a qualified electrician/ monter/ chimney 

sweeper. Comply with all local and national electrical and building codes when installing.

•  The best solution is to place smoke detectors in every room and on every floor of the building. 

Life-threatening smoke may not reach the detector if it is located in a remote place or encounters 

barriers (e.g. doors). In such cases, the smoke may not reach the alarm device in time to alert 

household members/ staff members. The sensor detects a fire in the room or area where it is 

installed.

•  The volume of the alarm sound is adjusted to the average hearing capacity to warn household 

members/ staff members of a potential danger. However, there may be limiting circumstances 

in which a person may not hear the alarm (e.g. outside or indoors noise, use of earplugs, use of 

drugs or alcohol, hearing impairment, etc.). A person hearing the alarm must respond quickly to 

it to reduce the risk of injury or death from a fire. If the household member/ staff member is deaf, 

install special smoke detectors with lights or vibration devices.

•  The smoke detector only sounds an alarm when smoke is detected. The sensor checks the com-

position of the air for the presence of particles that may come from the combustion process. The 

device does not detect high temperature, flames or gas. This smoke detector is designed to give 

an audible warning of a developing fire. In the event of violent fires involving explosions and oth-

ers smoke may not reach the detector quickly enough to allow for safe evacuation.

•  The smoke detector does not guarantee 100% protection of life/ health or property against fire. 

Smoke alarms are not a substitute for your insurance benefits. The sensor should be replaced after 

approximately 10 years. device weekly and replace every 10 years.

3. WHERE TO PLACE THE SMOKE DETECTOR

•  In a minimum home configuration, smoke detectors should be placed between the bedroom and 

potential fire locations such as the living room and kitchen. In one-story, one-bedroom houses, 

the smoke detector should be installed in the hallway, as close to the sleeping area as possible. 

To ensure the early recognition of dangers, no smoke detectors should be located more than 

3m from a door from a sleeping room. It may be necessary to install more than one smoke de-

tector, especially if the hallway is more than 15 m long. In single-story houses with two separate 

bedrooms, at least two smoke detectors are required, one near each sleeping area. In multi-sto-

rey houses, sensors should be installed on the ground floor between the staircase and all rooms 

where the fire may spread. Install at least one smoke detector on each floor in communication 

areas that form part of the escape route (usually hallway and mezzanines).

•  For the best protection, smoke detectors should be installed in every room in the home, except 

those listed in Chapter 4 LOCATIONS TO AVOID.

•  Smoke detectors should be installed in communication areas at a distance of no more than 7.5 m 

from the farthest wall, no more than 7.5 m from the door to any room where fire may start, and no 

more than 7.5 m from the next smoke detector.

•  The best location for the sensor is usually in the center of a room or hallway. If it is necessary to 

place the smoke detector on the wall, always place the detector’s sensor element 150 mm (0.15 m) 

GB

Summary of Contents for FS2SD

Page 1: ...GSM Smoke Detector User Manual ...

Page 2: ...se contrary to the intended use The FS2SD photoelectric sensor is effective at detecting slow smoldering fires that burn for hours before a flame develops as well as violent fires that quickly consume flammable materials and spread rapidly The smoke detector is equipped with a GSM communication module that communi cates with the cloud in Poland Data transmission takes place via the mobile telepho ...

Page 3: ...ars LED diode light signal approximately every 53 seconds to confirm that the device is powered Alarm module low battery warning sound signal beep approximately every 53 seconds when the battery level is low Pausing an alarm mute mode muting the alarm sound signal by pressing and holding the test button for 3 seconds when a non smoke gas e g steam triggers a false alarm In this mode the red LED di...

Page 4: ...e flames or gas This smoke detector is designed to give an audible warning of a developing fire In the event of violent fires involving explosions and oth ers smoke may not reach the detector quickly enough to allow for safe evacuation The smoke detector does not guarantee 100 protection of life health or property against fire Smoke alarms are not a substitute for your insurance benefits The senso...

Page 5: ...he danger Read Chapter 4 LOCATIONS TO AVOID one floor one sleeping area dining room living room kitchen sleeping room sleeping room sleeping room one floor more than one sleeping area TV room sleeping room dining room kitchen living room sleeping room sleeping room GB basement living room kitchen sleeping room sleeping room hall Smoke detectors for limited protection Additional smoke detectors for...

Page 6: ...ceiling at a distance of less than 300 mm 0 3 m from the edge of the wall In places with a lot of insects After getting inside the device small insects may affect the perfor mance of the device In very dusty or dirty places Dirt and dust can accumulate and reduce the performance of your device At a distance of 300 mm 0 3 m from lighting fixtures or room corners In places where it would be dangerou...

Page 7: ...ion Do not over tighten the screws as this will distort the mounting bracket This element should be firmly attached to the selected surface Line up the short marking line on the sen sor housing with the mounting bracket then rotate the sensor clockwise until the line on the sensor aligns with the long mar king line on the mounting bracket To prevent possible tampering insert the security pins into...

Page 8: ... This means that the smoke detector is in false alarm control mode If the smoke detector does not go into false alarm mode and continues to emit loud sound signal or if it initially goes into false alarm control mode and then goes off an alarm smoke is too intense and a dangerous situation may occur take emer gency action 8 SMOKE DETECTOR TESTING WARNING Test each installed smoke detector to make ...

Page 9: ...ork properly Clean the smoke detector at least once a month or depending on the environmental conditions in which it is installed Gently vacuum the out side of the smoke detector with a soft vacuum cleaner brush After maintenance work check the operation of the smoke detector Never use water cleaning agents or solvents as these may damage the device If the smoke sensor becomes contaminated with ex...

Page 10: ...flashes and the alarm beeps once every 53 seconds Low battery REPLACE SMOKE DETECTOR IMMEDIATELY Red LED flashes and smoke detector beeps twice every 53 seconds Clean alarm device OR REPLACE OR REPAIR The smoke detector emits false alarms intermittently 1 Clean the device see chapter 9 MAINTENANCE AND CLEANING 2 Move the smoke detector to another location See Chapter 3 WHERE TO PLACE THE SMOKE DET...

Page 11: ...Y Producer Ferguson Sp z o o ul Dworska 1 61 619 Poznań Name FS2SD GSM Device type Smoke detector The above mentioned product complies with Directive 2014 53 EU of the European Parliament and of the Council of 16 April 2014 on the harmonization of the laws of the Member States relating to the making available on the market of radio equipment and repealing Directive 1999 5 EC Full Declaration of Co...

Page 12: ...produced in PRC for Ferguson sp z o o ul Dworska 1 61 619 Poznań Poland www ferguson digital eu ...