Installation 3: Re RF Ther RF C Slave receiver(s)

1. Make the “Installation 2” rules for pairing with the thermostat and the Central.
2. The Master receiver (receiver paired with the thermostat & Central) must be put in Receiver RF init mode by 10sec pressing on the RF Button (V24/V26 master).
3. Then the RF LED should be Green/Red fixed indicating that the Receiver is now in radio configuration mode waiting for a thermostat configuration address.
4. Put now the Slave receiver in RF init mode by 2-10sec pressing on the ON/OFF button, then touch the button again to switch the socket to the slave mode 
(flashing BLUE/GREEN).
5. The Master and Slave receiver RF LED must be switched OFF to indicate correct paring between both elements.
6. You can link up to 3 Slave receivers on a Master receiver, to do this please repeat the steps 2 to 5 for each slave.

Note:

- The V25 slave receiver will follow the Master receiver.
- Only V25 receiver can be linked as a slave unit (Max 3 slaves).

Installation

 4: 

Receiver

 + Centr

al unit V24WIFI

 

1. 

The receiver must be put in RF init mode by 2-10sec pressing on the ON/OFF Button. 

2. Then the RF LED 

button

 should

 flashes Green and Red 

indicating that the Receiver is now in radio

 

configuration mode waiting for a

 V24 WIFI

 configuration 

address. 
3. 

Please refer to the Central unit V24 WIFI manual for installation procedure and adding ON/OFF zone.

 

4. 

 The receiver RF LED must be switched OFF and the Central  unit V24 WIFI will show a message to indicate correct pairing

 between both elements.

Note 1

- In this way the V25 Receiver will work in a Timer mode, you will have the possibility to create a weekly program for ON/OFF period.
- You can also add 3 slaves V25 receiver units in this configuration.

Note 2

In case of installation with V22 thermostat and loss of RF communication (RF Alarm), the receiver V25 will after 2 Hours cut off the power supply 
and start flashing in Green to indicate a signal was lost. 

INSTALLATION 1 :

INSTALLATION 2 :

INSTALLATION 3 :

INSTALLATION 4 :

Operating temperature
Shipping and storage 
Thermal safety temperature

0°C  40°C
-10°C až +50°C 
When > 85°C (back to the standard mode when 65°C)

Power supply

90- 230VAC 50Hz (with European plug socket) 

Electrical protection

Class II - IP20 

Output

Maximum R

e

sistive Load Relay

Relay 10Amps
250VAC 50Hz 

Radio Frequency & RF 
Receiving distance

868MHz < 10mW (Bidirectional communication)
100m in open space
30m in residential environment

Directive 2001/95/EC on General Products Safety Low voltage directive 
2006/95/EEC Radio Equipment Directive 1995/5/EC-2014/53/EU ROHS 
Directive 2011/65/EC The full text of the EU declaration of conformity is available 
on wattswater.eu 

Product confirmed on
Class
Contribution

UE 811/2013 and 2010/30/UE 
IV
2%

Standards and approvals:

Your thermostat has been designed accordingly
with the following standards and other normative documents

« The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding.

 Fenix Trading s.r.o.

reserves the right to carry out 

any technical and design improvements to its products without prior notice. Warranty: All sales and contracts for sale are expressly  conditioned on the buyer’s assent to 

Fenix

 terms and 

conditions found on its website at 

fenixgroup.cz 

Fenix

 hereby objects to any term, different from or additional to 

Fenix

 terms

.

MASTER

SLAVE (max.3x)

Quick Installation Manual (ENG)

Summary of Contents for Watts V25 PLUG-IN

Page 1: ...ujte a zapojte přijímač dle následujících pokynů Přijímač musí být umístěn ve vzdálenosti minimálně 50 cm od veškerých jiných elektrických a bezdrátových zařízení jako je GSM Wi Fi router Zapojte přijímač do zásuvky Pro správnou inicializaci RF je nutné dodržet následující postup Kombinace 1 Přijímač termostat RF 1 Přijímač V25 musí být přepnut na VYPNUTO stisknutím tlačítka ZAPNUTO VYPNUTO 2 Přij...

Page 2: ...rávně spárovány Poznámka 1 Tímto způsobem bude přijímač V25 pracovat v režimu Časovač budete mít možnost vytvořit týdenní program ZAPNUTO VYPNUTO V této konfiguraci můžete přidat 3 závislé jednotky V25 Poznámka 2 V případě instalace s termostatem V22 a ztrátou RF komunikace RF Alarm přijímač po 2 hodinách přeruší napájení a začne blikat zeleně aby signalizoval ztrátu signálu KOMBINACE 1 KOMBINACE 2...

Page 3: ...off position or heating position it depends on thermostat set temperature Thermostat should exit the RF init mode to indicate correct paring between both elements Installation 2 Receiver RF Thermostat RF Central 1 Make the Installation 1 rules for pairing with the thermostat 2 The receiver must be put one time more in RF init mode by 2 10 sec pressing on the On Off Button 3 Then the RF LED button sh...

Page 4: ... will work in aTimer mode you will have the possibility to create a weekly program for ON OFF period You can also add 3 slaves V25 receiver units in this configuration Note 2 In case of installation with V22 thermostat and loss of RF communication RF Alarm the receiver V25 will after 2 Hours cut off the power supply and start flashing in Green to indicate a signal was lost INSTALLATION 1 INSTALLATION...

Reviews: