www.fenixgroup.cz
Fenix Trading s.r.o., Slezská 2790 01 Jeseník, Czech republic
+420 584 495 111
Installation 3: Re RF Ther RF C Slave receiver(s)
1. Make the “Installation 2” rules for pairing with the thermostat and the Central.
2. The Master receiver (receiver paired with the thermostat & Central) must be put in Receiver RF init mode by 10sec pressing on the RF Button (V24/V26 master).
3. Then the RF LED should be Green/Red fixed indicating that the Receiver is now in radio configuration mode waiting for a thermostat configuration address.
4. Put now the Slave receiver in RF init mode by 2-10sec pressing on the ON/OFF button, then touch the button again to switch the socket to the slave mode
(flashing BLUE/GREEN).
5. The Master and Slave receiver RF LED must be switched OFF to indicate correct paring between both elements.
6. You can link up to 3 Slave receivers on a Master receiver, to do this please repeat the steps 2 to 5 for each slave.
Note:
- The V25 slave receiver will follow the Master receiver.
- Only V25 receiver can be linked as a slave unit (Max 3 slaves).
Installation
4:
Receiver
+ Centr
al unit V24WIFI
1.
The receiver must be put in RF init mode by 2-10sec pressing on the ON/OFF Button.
2. Then the RF LED
button
should
flashes Green and Red
indicating that the Receiver is now in radio
configuration mode waiting for a
V24 WIFI
configuration
address.
3.
Please refer to the Central unit V24 WIFI manual for installation procedure and adding ON/OFF zone.
4.
The receiver RF LED must be switched OFF and the Central unit V24 WIFI will show a message to indicate correct pairing
between both elements.
Note 1
:
- In this way the V25 Receiver will work in a Timer mode, you will have the possibility to create a weekly program for ON/OFF period.
- You can also add 3 slaves V25 receiver units in this configuration.
Note 2
:
In case of installation with V22 thermostat and loss of RF communication (RF Alarm), the receiver V25 will after 2 Hours cut off the power supply
and start flashing in Green to indicate a signal was lost.
INSTALLATION 1 :
INSTALLATION 2 :
INSTALLATION 3 :
INSTALLATION 4 :
Operating temperature
Shipping and storage
Thermal safety temperature
0°C 40°C
-10°C až +50°C
When > 85°C (back to the standard mode when 65°C)
Power supply
90- 230VAC 50Hz (with European plug socket)
Electrical protection
Class II - IP20
Output
Maximum R
e
sistive Load Relay
Relay 10Amps
250VAC 50Hz
Radio Frequency & RF
Receiving distance
868MHz < 10mW (Bidirectional communication)
100m in open space
30m in residential environment
Directive 2001/95/EC on General Products Safety Low voltage directive
2006/95/EEC Radio Equipment Directive 1995/5/EC-2014/53/EU ROHS
Directive 2011/65/EC The full text of the EU declaration of conformity is available
on wattswater.eu
Product confirmed on
Class
Contribution
UE 811/2013 and 2010/30/UE
IV
2%
Standards and approvals:
Your thermostat has been designed accordingly
with the following standards and other normative documents
« The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding.
Fenix Trading s.r.o.
reserves the right to carry out
any technical and design improvements to its products without prior notice. Warranty: All sales and contracts for sale are expressly conditioned on the buyer’s assent to
Fenix
terms and
conditions found on its website at
fenixgroup.cz
-
Fenix
hereby objects to any term, different from or additional to
Fenix
terms
.
MASTER
SLAVE (max.3x)
Quick Installation Manual (ENG)