Instructions for use and installation
Radiant electric heating panel: ECOSUN S+
ECOSUN S+ ANTICOR
1.
Basic technical data
* version Ecosun S+
2
.
Use
Radiant panels are intended for the heating of large spaces, mainly industrial halls and workshops, etc., warehouses, shops, function halls
and sports halls. They can also be used for the local heating of designated areas (zonal temperature maintenance).
The
Ecosun S+ ANTICOR
model is intended for environments with an increased risk of corrosion.
The panel is constructed for use in environments with splashing water. However, rapid cooling of the panel when it is hot can result in
irreversible damage to it.
3. Installation
Installation of these panels may only be carried out by a person with a specialized qualification. The electrical
wiring must comply with the valid norms in the country of installation. The panels can either be hung from the
ceiling on four fixtures using a chain or cords, or with the help of installation brackets. The minimum load of
the applied chain and wire rope must be 100 kg. The brackets are supplied disassembled in the terminal and
need to be attached before installation of the panel. The brackets can be supplemented with a swivel bracket
– an inclinable bracket (not part of the product package).
The radiant panel can be installed at an angle as well as vertically. However it must not be installed at an
angle or vertically in such a way that the terminal is the highest part of the panel. There is higher convection
of heat when the panel is in a tilted position and this heat would irreversibly damage the electrical compo-
nents of the terminal.
Type
Wattage
W
Voltage
V
Protection
class
IP
Dimensions
mm
Weight
kg
ECOSUN S+ 06 *
600
230/400V 3N
I
IP 44
650 x 250 x 60
ECOSUN S+ 08 *
850
ECOSUN S+ 09
900
230 V 1N
1550 x 150 x 60
7,8
ECOSUN S+ 12
1200
ECOSUN S+ 18
1800
230/400V 3N
1550 x 250 x 60
12,35
ECOSUN S+ 24
2400
ECOSUN S+ 30
3000
1550 x 350 x 60
16,65
ECOSUN S+ 36
3600
4,9