Feniex FUSION FN-1116 Instruction Manual Download Page 5

WIRING, CONFIGURATION, & MOUNTING INSTRUCTIONS

COLOR

FUNCTION POLARITY

CONNECTION

  Red

Mode 1

12v (+)

Latching Switch

  Black

Gound

12v (-)

Chasis Ground

  Green

Pattern

Changer/

Sync

12v (-)

Momentary Switch 

  White

Mode 2

12v (+)

Latching Switch 

WIRING DIAGRAM

SETTING MASTER/SLAVE

 

For the light heads to alternate, one light head must be 

set as master and the other as slave on the mode wire 

intended for use. To do so, hold the green (flash pattern 

changer) wire to ground for 3 seconds. 

For Single color: if all LEDs turn on, this indicates master 

mode. If no LEDs turn on, this indicates slave mode. 

For Dual color: if all LEDs turn on, this indicates master 

mode. If half of the LEDs turn on, this indicates slave 

mode.

POWER 

To operate the cigarette plug option, plug in the provided 

lighter plug into the vehicle's cigarette lighter plug outlet. 

Turn the unit on with the On/Off switch and change 

patterns with the momentary flash pattern changer.

PATTERNS & SYNCHRONIZATION

1)

 Momentarily tap the green wire to a ground 12v (-) 

source to cycle through the flash patterns.

2)

 Synchronization: To synchronize two or more Fusions 

(or compatible products) together:

 A)

 Choose the desired flash pattern for each unit.

 B)

 Connect the green wires of the light heads    

 together.

To achieve syncronization, the patterns must match on all 

products connected to the synchornization circuit.

Each time the master/slave mode is set, the pattern will reset 

to the default setting (Single Flash [Slow]). This simplifies the 

process of synchronizing two or more compatible products.

The Fusion 1X & 2X can be synchronized with other compatible 

products with matching patterns (single color). Consult the 

instruction manual of each product as the process may differ 

by model. 

MOUNTING INSTRUCTIONS:

SUCTION CUP:

Make sure the suction cups have been cleaned with 

alcohol to remove all residue.

Stick lights onto the interior of the vehicle dash window.

PERMANENT MOUNT:

Cleaning Instructions:

1. 

To obtain optimum adhesion, use a non-amonia based 

de-greaser to clean the surface you will adhere the mount 

to.

2.  

Place tape inside the surface mount and press onto 

back of Fusion 1X or 2X with 15 psi's of pressure. Full 

adhesion is reached after 72 hours. 

Refer to 3M Surface preparation document for detailed 

instructions.

Surface Prep:

http://multimedia.3m.com/mws/media/66019O/

vhbtm-tape-surface-preparation-technical-bulletin.

pdf?&fn=87015.pdf

Tape Product Description:

https://multimedia.3m.com/mws/media/67100O/3mtm-

vhb-tapes.pdf

Mode 2

Mode 2

Flash Pattern

Flash Pattern

Mode 1

Mode 1

Single Color

Dual Color

FENIEX

 

//

 2019 

// INSTRUCTION MANUAL // v3.0

WEB

 

//

 

www.feniexindustries.com

5

TM

Reviews: