67
7. Installation of electrical devices
Pin name
Assignment
Safeguarded
Designation
S2
Earth from power supply
S1
12 V from power supply
S41
2 x earth and 2 x plus from battery 9/13
S38
Earth and plus to charging controller for rally package
S39
Earth and plus to charging controller for rally package
S40
Earth and plus 10/11 for rally package
A1
Earth and plus (water pump)
10 A fuse
A
A2
Earth and plus (Porta Potti toilet)
10 A fuse
A3
Earth and plus (12V, plug sockets)
10 A fuse
A4
Earth and plus
10 A fuse
B2
Earth and plus (antenna)
10 A fuse
B
B3
Earth and plus (combi heating or circulation fan)
10 A fuse
B4
Earth and plus (circulation fan)
10 A fuse
B5
Earth and plus + steady plus (radio)
10 A fuse
B6
Earth and steady plus (Wi-Fi)
10 A fuse
B7
Earth and steady plus (Tec-Tower)
10 A fuse
B8
Earth and steady plus
10 A fuse
C1
Earth and plus (lighting in living room)
5 A fuse
C
C2
Earth and plus (lighting in kitchen)
5 A fuse
C3
Earth and plus
5 A fuse
D1
Earth and 2 x plus for ceiling light in bedroom
5 A fuse
D
D2a= plus upper LED strip overhead stowage compartment
5 A fuse
D2
D3a= plus lower LED strip overhead stowage compartment and lighting for corner shelf
5 A fuse
Earth and plus
5 A fuse
D2b
Earth and plus LED strip
5 A fuse
D3b
Earth and plus LED strip superstructure
5 A fuse
D5
Earth and plus
5 A fuse
E1
Earth and 2 x plus for ceiling lights in living room
7.5 A fuse
E
E2a = plus upper LED strip overhead stowage compartment
7.5 A fuse
E2
E3a= lower LED strip overhead stowage compartment and lighting for corner shelf
7.5 A fuse
Earth and plus
7.5 A fuse
E2b
Earth and plus upper LED strip overhead stowage compartment
7.5 A fuse
E3b
Earth and plus lower LED strip overhead stowage compartment and lighting for corner shelf 7.5 A fuse
E4
Earth and plus
7.5 A fuse
E5
Earth and plus LED strip for bar
7.5 A fuse
F1
Earth and plus outer tent light, LED lighting for step
7.5 A fuse
F
F2
Earth and plus awning rail lighting
7.5 A fuse
F3
Earth and plus downlighters
7.5 A fuse
F4
Earth and plus
7.5 A fuse
S46
Input 230 V phase and neutral
S35
Input 230 V boiler
S34
Output 230 V floor heating
PE1
Protective earth input 230 V
PE2
Protective earth output boiler
PE3
Protective earth output floor heating
PE4
Protective earth connector for connection to earth power supply low voltage
PE5
Connector earth power supply/devices for connection to protective earth
Control panel in bedrooms, keys 1,7,8,9,C
Control panel in bedroom keys 1,7,8,9,C
Control panel external lighting
Main panel
7x Ci-Bus
Pin assignment for the switch box