Fender SPL-6000P Owner'S Manual Download Page 4

G - MODE SELECT MONO BRIDGED/STEREO 

This two-position switch (left rear panel) selects either the
mono bridge or normal stereo mode.   With the button in
the "in" position, the amplifier is in the mono bridged
mode.  With the button in the "out" position, the amplifier
is configured for the normal two-channel stereo mode of
operation.  In the Bridged Mode of operation, speaker out-
put is taken across the two red (positive) output terminals.
The Channel A terminal is the positive output terminal and
the Channel B terminal is the negative terminal for bridged
operation only.

CAUTION: In the Bridged Mode of operation, 
the load floats and is NOT chassis ground
referenced.

H - MODE SELECT, DUAL MONO/STEREO

This two-position switch connects the amplifier inputs
together to allow channel A and B to be summed (mixed) 
for non-bridged mono operation.  In the dual mono and
the stereo mode of operation, both attenuators control 
their respective channels.

I, J & K - INPUT CONNECTORS

Each channel is provided with a Female XLR (I) and Male
XLR (J) connectors for easy "Daisy Chain" operation 
of multiple channels in large systems, and a 1/4" inch tip-
ring-sleeve (stereo) phone jack (K).  Each input is electroni-
cally balanced and will accept signals from balanced
sources (either active or transformer) or from unbalanced
circuits.  Pin #2 is the positive pin on the XLR connectors.  

L - AC POWER CORD

WARNING:  This amplifier is equipped with a 3-
prong, grounding type supply cord.  To reduce
the possibility of shock hazard, be sure to con-
nect the unit to a grounded AC recepticle.  DO
NOT ALTER THE AC PLUG!  

100-120V OPERATION 

This must be connected to a source of 100V or 120V, 50 to
60 Hz AC power with a current capability of at least 10 A.
As a general guideline, it is accepted to connect two (2) SPL-
6000 amplifiers to one (1) 20 ampere circuit provided the
load is limited to 4-ohm loudspeakers on each channel and
the signal source is full range music or speech.  

220-240V OPERATION

This must be connected to a source of 220-240V, 50 to 60 Hz
AC power with a current capability of at least 5 A. 

M - EXTERNAL FUSE

When necessary, replace the external fuse only with one of
the same type and rating as shown on the label 
next to the external fuse holder.

4

TYPE: PR200

CAUTION:

 

 CHASSIS SURFACE HOT

WARNING:

 

TO REDUCE THE RISK OF FIRE OR

ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT

TO RAIN OR MOISTURE

A PRODUCT OF:

FENDER MUSICAL

INSTRUMENTS CORP.,

CORONA,  CA  91720

300 WATTS

4 OHM MINIMUM

300 WATTS

4 OHM MINIMUM

600 WATTS

8 OHM MINIMUM

LOAD BRIDGED

TIP

RING

= (+)
= (–)

1/4"
PHONE

FOR MONO BRIDGE

OPERTION, USE

MONO
BRIDGE

DUAL

MONO

ATTENTION:

UTILISER UN
FUSIBLE DE
RECHANGE
DE MEME

CAUTION:

TO REDUCE

THE RISK OF

FIRE, REPLACE

FUSE WITH

K

H

G

K

I

I

J

J

E

E

F

F

M

L

SERIAL

Summary of Contents for SPL-6000P

Page 1: ...Power Amplifiers From Fender Pro Audio Owner s Manual for SPL 6000 P N 038866 ...

Page 2: ...ontrols on the source set as they were If the system is noisy hissy reduce the setting of the INPUT LEVEL control s slightly and repeat this step You must juggle the settings of the source s controls until you find a combination that gives you the desired amplifier output freedom from clipping caused by excessive output demands placed on signal source and poor signal to noise performance caused by...

Page 3: ...volt age is present If this indicator does not light when the power switch is turned on and does not trip the circuit breaker then check the AC power supply 2 REAR PANEL E F OUTPUT CONNECTORS Each channel is provided with a single 1 4 phone jack E and a pair of five way binding posts F which will accommodate a single pair of dual banana plugs multiple stacked banana plugs are not recommended as th...

Page 4: ... transformer or from unbalanced circuits Pin 2 is the positive pin on the XLR connectors L AC POWER CORD WARNING This amplifier is equipped with a 3 prong grounding type supply cord To reduce the possibility of shock hazard be sure to con nect the unit to a grounded AC recepticle DO NOT ALTER THE AC PLUG 100 120V OPERATION This must be connected to a source of 100V or 120V 50 to 60 Hz AC power wit...

Page 5: ...are fed all of the amplifier s power without the need for heavy cables This can actually save money in many instances Always use stranded wire for three reasons 1 It is more flexible and less prone to metal fatigue breakage 2 If an end is nicked while insulation is being stripped for connection only one or two strands will break and not the entire wire 3 There is some evidence though disputed that...

Page 6: ...he suitability of any cleanser Assuming you are NOT turning all the equipment on at once with a switched power receptacle strip be sure to turn on the power amplifier last This will prevent turn on thumps from the mixer or other pieces of gear that could possibly damage speakers The reverse logic should also be applied turn OFF the amplifier FIRST when shut ting down the system The SPL 6000 is tim...

Page 7: ...20 kHz broad band 95 dB IEC A Weight 102 dB DAMPING FACTOR Reference 8 Ω 5 Hz to 20 kHz Greater than 30 1 kHz Greater than 175 INPUT IMPEDANCE Differential 33 kΩ CHANNEL SEPARATION Below rated power single channel operating 1 kHz Greater than 65 dB SENSITIVITY Referenced 1 kHz 0 25 dB Stereo Mode 1 8 dBV 1 23V Bridged Mode 1 8 dBV STATUS INDICATORS Each channel Peak LED red Power LED green COOLING...