background image

Important  Safety  InStructIonS

  This  symbol  warns  the  user  of  dangerous  voltage  levels  localized  within  the 

enclosure.

  This symbol advises the user to read all accompanying literature for safe operation 

of the unit.

  Read, retain, and follow all instructions.  Heed all warnings.

  Only connect the power supply cord to an earth grounded AC receptacle in accordance with the 

voltage and frequency ratings listed under INPUT POWER on the rear panel of this product.

 

WARNING: 

  To  prevent  damage,  fire  or  shock  hazard,  do  not  expose  this  unit  to  rain  or 

moisture.

  Unplug the power supply cord before cleaning the unit exterior (use a damp cloth only).  Wait 

until the unit is completely dry before reconnecting it to power.

  Maintain at least 6 inches (15.25 cm) of unobstructed air space behind the unit to allow for 

proper ventilation and cooling of the unit.

  This product should be located away from heat sources such as radiators, heat registers, or 

other products that produce heat.

  This product may be equipped with a polarized plug (one blade wider than the other).  This is 

a safety feature.  If you are unable to insert the plug into the outlet, contact an electrician to 
replace your obsolete outlet.  Do not defeat the safety purpose of this plug.

  Protect the power supply cord from being pinched or abraded.

  This  product  should  only  be  used  with  a  cart  or  stand  that  is  recommended  by  the 

manufacturer.

  The power supply cord of this product should be unplugged from the outlet when left unused 

for a long period of time, or during electrical storms.

  This product should be serviced by qualified service personnel when: the power supply cord or 

the plug has been damaged; or objects have fallen, or liquid has been spilled onto the product; 
or the product has been exposed to rain; or the product does not appear to operate normally or 
exhibits a marked change in performance; or the product has been dropped, or the enclosure 
damaged.

  Do not drip nor splash liquids, nor place liquid filled containers on the unit.

 

CAUTION:

  No user serviceable parts inside, refer servicing to qualified personnel only.

  Fender®  amplifiers  and  loudspeaker  systems  are  capable  of  producing  very  high  sound 

pressure levels which may cause temporary or permanent hearing damage.  Use care when 
setting and adjusting volume levels during use.

FCC  COMPLIANCE  STATEMENT: 

This equipment has been tested and found to comply with the 

limits of Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment generates, uses and can radiate 
radio frequency energy and, if not installed and used in accordance with the instructions, may 
cause harmful interference to radio communications. However, there is no guarantee that interfer-
ence will not occur in a particular installation. If this equipment does cause harmful interference 
to radio or television reception, which can be determined by turning the equipment off and on, 
the user is encouraged to try to correct the interference by one or more of the following measures: 
•Reorient or relocate the receiving antenna.  •Increase the separation between the equipment and 
receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver 
is connected. •Consult the dealer or an experienced radio/TV technician for help.

ENGLISH - PAGES  .  .  .  .  .  .  .  .  .  .  . 6-8

ESPAÑOL   - PAGINAS  .  .  .  .  .  .  . 9-11

FRANÇAIS - PAGES  .  .  .  .  .  .  .  .  .  . 12-14

ITALIANO   - PAGINE  .  .  .  .  .  .  .  . 15-17

DEUTSCH - SEITEN  .  .  .  .  .  .  .  .  .  . 18-20

PORTUGUÊS - PAGINA .  .  .  .  .  .  . 21-23

  

          .  .  .  .  .  .  .  .  .  .  .  .  . 24-26

Summary of Contents for Princeton Recording Amp

Page 1: ......

Page 2: ...eplughasbeendamaged orobjectshavefallen orliquidhasbeenspilledontotheproduct ortheproducthasbeenexposedtorain ortheproductdoesnotappeartooperatenormallyor exhibits a marked change in performance or the product has been dropped or the enclosure damaged Do not drip nor splash liquids nor place liquid filled containers on the unit CAUTION No user serviceable parts inside refer servicing to qualified ...

Page 3: ...nuation with full interaction between the power amp and the speaker Crank up the amp for full output tube overdrive then set the volume of the speaker as low as you want The feel and bounce back dynamics of the speaker are reflected back to the tube amp and the player s hands NOT housemates or family members The patented circuit eliminates the stiff lifeless playing feel of other power attenuators...

Page 4: ...ket Connect to a grounded outlet using the supplied power cord in accordance with the voltage and frequency ratings specified on the rear panel of your amplifier R power Turns the Princeton Recording Amp ON OFF S SPEAKER OUTPUT Connection for the speaker CAUTION An 8Ω speaker must always be connected when the amplifier is ON or damage may occur T HEADPHONE A speaker emulated output for use with st...

Page 5: ...INPUT IMPEDANCE 1MΩ Input 1 136kΩ Input 2 SENSITIVITY AT FULL POWER 20mV EFFECTS LOOP SEND IMPEDANCE 1kΩ RETURN IMPEDANCE 10kΩ LINE OUT SEND IMPEDANCE 3 3kΩ FUSES 100V 120V MODELS F5A L 250V 0037588000 220V 240V MODELS F2 5A L 250V 0020795000 SPEAKER 8Ω 10 Jensen C 10R P N 0069347000 FOOTSWITCH 4 button Overdrive Compressor FX Loop Reverb 0065911000 DIMENSIONS HEIGHT 16 5 in 42 cm WIDTH 20 in 51 c...