FEMA ELECTRÓNICA . Series M . M60-P
3
1.2 Front view
1.3 Rear view
Earth connection - Although a
terminal is provided for earth
connection, this connection is
optional. The instrument does
not need earth connection for
correct operation nor for com
-
pliance with the security regu
-
lations.
~
~
+
-
8 9 0
Fuse - To comply with security regulation 61010-1, add to the power
line a protection fuse acting as disconnection element, easily acces
-
sible to the operator and identified as a protection device.
Power ‘H’
fuse 250 mA time lag
Power ‘L’
fuse 400 mA time lag
1.4
Power connections
1.5
Signal connections
Button ‘UP’
Logo
Alarms
Units
Button ‘SQ’
Button ‘LE’
‘Configuration menu’
‘Fast access‘
1.6 Mechanical dimensions (mm)
Signal
Jumpers
Option 1
Option 2
Option 3
Power
Detail of the plug-in screw terminals provided with
the instrument. The instrument is provided with all
terminals needed, both male and female.
8 9 0
4
5
44
92
Panel
cut-out
16
8
75
Common
Signal
1 2 3
4 5
Jumper 5
closed
Figure 1 - External power current
loop (4/20 mA/ ±20 mA)
Vexc.
Signal
1 2 3
4 5
Jumper 5
closed
Figure 2 - Current loop powered
from M60-P (4/20 mA/ ±20 mA)
Common
Signal
1 2 3
4 5
Jumper 4
closed
Figure 3 - Active voltage
(0/10 Vdc/ ±10 Vdc)
Vexc.
1 2 3
4 5
Jumper 4
closed
Common
Signal
Figure 4 - Passive voltage
(0/10 Vdc/ ±10 Vdc)
Pot.
Vexc. +5V
1 2 3
4 5
Jumper 4
closed
Common
Signal
Figure 5 - Potentiometer
96
48