Fema Electronica M60-P User Manual Download Page 3

FEMA ELECTRÓNICA . Series M . M60-P

3

1.2 Front view

1.3 Rear view

Earth  connection  -  Although  a 

terminal  is  provided  for  earth 

connection,  this  connection  is 

optional.  The  instrument  does 

not  need  earth  connection  for 

correct operation nor for com

-

pliance with the security regu

-

lations.

~

~

+

-

8  9  0

Fuse - To comply with security regulation 61010-1, add to the power 

line a protection fuse acting as disconnection element, easily acces

-

sible to the operator and identified as a protection device.
 

Power ‘H’  

fuse 250 mA time lag

 

Power ‘L’ 

fuse 400 mA time lag

1.4 

Power connections

1.5 

Signal connections

Button ‘UP’

Logo

Alarms

Units

Button ‘SQ’

Button ‘LE’

‘Configuration menu’

 

(see section 1.10)

‘Fast access‘ 

(see section 1.10.6)

1.6 Mechanical dimensions (mm)

Signal 

(see section 1.5)

Jumpers

 

(see section 1.5)

Option 1

Option 2

Option 3

Power

 

(see section 1.4)

Detail of the plug-in screw terminals provided with 

the instrument. The instrument is provided with all 

terminals needed, both male and female.

8 9 0

4

5

44

92

Panel 

cut-out

16

8

75

Common

Signal

 1 2 3

4 5

Jumper 5 

closed

Figure 1 - External power current 

loop (4/20 mA/ ±20 mA)

Vexc.

Signal

1 2 3

4 5

Jumper 5 

closed

Figure 2 - Current loop powered 

from M60-P (4/20 mA/ ±20 mA)

Common

Signal

1 2 3

4 5

Jumper 4 

closed

Figure 3 - Active voltage 

(0/10 Vdc/ ±10 Vdc)

Vexc.

1 2 3

4 5

Jumper 4 

closed

Common

Signal

Figure 4 - Passive voltage 

(0/10 Vdc/ ±10 Vdc)

Pot.

Vexc. +5V

1 2 3

4 5

Jumper 4 

closed

Common

Signal

Figure 5 - Potentiometer

96

48

Summary of Contents for M60-P

Page 1: ...fast access to alarm setpoints tare function on power up function measure function configurable reading brightness Universal AC and DC power Up to 3 optional modules for output and control relays tran...

Page 2: ...m and minimum reading password protection 5 brightness levels Index 1 Panel meter M60 P 2 1 1 How to order 2 1 2 Front view 3 1 3 Rear view 3 1 4 Power connections 3 1 5 Signal connections 3 1 6 Mecha...

Page 3: ...SQ Button LE Configuration menu see section 1 10 Fast access see section 1 10 6 1 6 Mechanical dimensions mm Signal see section 1 5 Jumpers see section 1 5 Option 1 Option 2 Option 3 Power see sectio...

Page 4: ...5 W only meter 4 0 W meter with options Configuration 3 buttons front keypad and rear jumper 1 7 Technical specifications Ranges Accuracy Zin Max signal overload 4 20 mA 0 03 FS 11 Ohm 100 mA permanen...

Page 5: ...E 3 inside the menus the LE 3 key functions as the ES CAPE key It leaves the selected menu and eventually will leave the whole menu When leaving the configuration menu with the LE 3 key the changed pa...

Page 6: ...imum input signal The Field correction F cor functions allows to correct the instrument scaling parameters when the instrument is being installed on the field providing a fast and easy way to compensa...

Page 7: ...ing of the alarm relays due to fluctuating input signals around the set point at Activation delay dEL 0 configure the delay to apply before alarm activation The activation delay starts counting when t...

Page 8: ...ry of maximum MAX function displays the maximum reading value stored in memory It also provides a way to reset the value This parameter is eligible for configuration through the Fast access menu see s...

Page 9: ...nt gives access to a list of functions configurable by the operator See section 1 8 for an ex planation on how to operate the fast access menu The Key UP Fast access K uP menu allows to select which f...

Page 10: ...rE menu allows to operate the instrument for load cell and weight applications The tare function assigns the actual input signal value to a reading of 0 Kilos by adding an inter nal offset It does not...

Page 11: ...access the configuration menu key SQ The fast access menu is not password pro tected 1 10 12 Function Password At the Brightness LIGh menu select the light intensity for the front leds With this funct...

Page 12: ...0 to 100 Display Fixed digits Memory of maximum Memory of minimum Peak Hold Time seconds Alarm 2 menu Alarm 3 menu Relay inverted Locked alarm Alarms Alarm 1 Setpoint Hysteresis Active Alarm type Fiel...

Page 13: ...f segments Value 2 to 31 Input 0 Display 0 Input 1 Display 1 On power up Delay Tare Seconds Option 1 Configuration menu for the module installed at Opt 1 Option 2 Configuration menu for the module ins...

Page 14: ...that all modules are correctly connected to the pins on the display module Place all the set into the housing assuring that the modules correctly fit into the internal guiding slides of the housing O...

Page 15: ...d off Brightness 3 strument must be assured Do not expose the instrument to excess of humidity Maintain clean by using a humid rag and do NOT use abrasive products such as alcohols solvents etc Genera...

Page 16: ...tinuous Isolation 3500 Veff Type of terminal plug in screw terminal pitch 5 08 mm Slots allowed Opt 1 Opt 2 Opt 3 Terminal A Common Terminal B NO Normally open Terminal C NC Normally closed Power Opt...

Page 17: ...pecial configuration Terminal A Vexc Terminal B Signal in mA or Vdc Terminal C GND Jumper M closed for mA Jumper V closed for Vdc For more information http fema es docs 4254_SERIES_M K S_ OPTIONS_manu...

Page 18: ...Opt 2 Opt 1 Opt 3 B A G B A G Signal B A G Terminal B B signal from RS 485 bus Terminal A A signal from RS 485 bus Terminal G GND For more information http fema es docs 4254_SERIES_M K S_ OPTIONS_manu...

Page 19: ...rograms Access to display values alarm status memory of maximum and minimum alarm setpoints Configuration from instrument front keypad through menu entries Opt 1 Opt 2 or Opt 3 depending on the positi...

Page 20: ...out front key pad To configure the instrument remove the meter from the panel and remove the front filter Inter nal press buttons for configuration are accessible Optionally request the instrument pre...

Page 21: ...1 THM benchtop housing Adapter96 x 96 mmfor96 x 48 mm instruments Adapter for DIN rail mount for Series M and Series K of panel meters Wall mount housing Together with the KIP protector offer a full...

Page 22: ...FEMA ELECTR NICA Series M M60 P 22 Notes...

Page 23: ...FEMA ELECTR NICA Series M M60 P 23 Notes...

Page 24: ......

Reviews: