Series BDF

Large Displays for frequencies

Large 

Displays

FEMA ELECTRÓNICA

USER’S MANUAL

(1276R02)

IDEAL SOLUTION for reading values scaled in «meters per minute», «RPM», 

«m3 per hour»,...  at long distances, from standard «impulse per second» 

signals. Very strong housing and electrically protected units, designed for all 

type of industrial applications.

BDF-xx-TF   Ratemeter

Summary of Contents for BDF Series

Page 1: ...R S Manual 1276r02 IDEAL SOLUTION for reading values scaled in meters per minute RPM m3 per hour at long distances from standard impulse per second signals Very strong housing and electrically protect...

Page 2: ...ive and is firmly inserted on the aluminium profile with a rubber gasket around providing IP65 protection on the front The signal wires are connected to plug in screw clamps for higher security of the...

Page 3: ...optional Powered 24 Vdc Isolated Fuse Rear view Power includes fuse Programming Terminal Terminal for input impulses and control A B D Front view Decimal point selectable Negative sign Negative sign D...

Page 4: ...terminals 28Vdc PNP Vmax on terminals 28Vdc Namur Vmax on terminals 28Vdc mechanical contact Pick up PICK UP 150 mVpp sensibility 100 mV hysteresis 26 5 KOhms Impedance 60Hz Vmax 50Vdc Note Sensor ty...

Page 5: ...minals C Input1 and A Common E D C INPUT1 B Vexc A COMMON RESET MECHANICAL CONTACT Jumpers ADF INPUT1 terminal C Signal and A Common Note close internal jumpers J K See section 6 Sensor type selection...

Page 6: ...4 5 6 7 8 9 10 11 12 13 14 15 Pin 1 common Pin 9 button Pin 2 button 6 Pin 10 button 5 Pin 3 button 4 Pin 11 button 3 Pin 4 button 2 Pin 12 button 1 Pin 5 button ENTER Pins 6 13 and 14 shortcircuited...

Page 7: ...600 63 1 Time Base between 0 5 and 1 seconds 63 2 Time Base between 1 and 2 seconds 63 3 Time Base between 2 and 4 seconds 63 4 Time Base between 4 and 8 seconds 63 5 Time Base between 8 and 16 second...

Page 8: ...equency in impulses per second The Time Base also de fines the refresh on display By default the Time Base of 0 5 to 1 second will be enough In case the signal is too slow 0 1 impulses per second for...

Page 9: ...A B C Note add 27mm to the C dimension for the power supply plug 4 digits 57mm 264mm 120mm 112mm 2 10 40 4 75 4 41 Size 24 A B C 4 digits 100mm 480mm 180mm 112mm 4 18 90 7 09 4 41 Size 44 A B C Mecha...

Page 10: ...uments indicated comply with the directives and rules indicated below Directive of electromagnetic compatibility 2004 108 CEE Directive of low voltage 73 23 CEE Security rules 61010 1 Emission rules 5...

Page 11: ...User s Manual BDF xx TF FEMA ELECTR NICA Page 11 S E C T I O N B L A N K...

Page 12: ...ucts ELECTRONIC INSTRUMENTATION FOR INDUSTRY www fema es FEMA ELECTR NICA S A Altimira 14 Pol Ind Santiga E08210 Barber del Vall s BARCELONA SPAIN Tel 34 93 729 6004 www fema es Fax 34 93 729 6003 inf...

Reviews: