The common features for all series are the following:
MECHANICAL
.-
Housed in a rugged extruded aluminium profile housing for panel mounting or free standing.
Finished in anodized black colour. The frontal lens is mounted with a special rubber profile
which
provides the front part of the unit with an IP-65 protection.
SIGNAL INPUT.-
All series have two channel inputs. Channel 1 serves as the count in every Response Mode
and
Channel 2 serves as the control function or to count.
Both Channels accept signal generates by NAMUR, PNP or NPN sensor types and contact
closure. Magnetic PICK-UP sensor is only accepted by Channel 1.
CONNECTIONS.-
Connections for Signal Inputs or control functions are made using one screw-clamp
connector
of five terminals located on the rear part of the unit.
The recommended wire cross section is 1 mm
2
.
Connection for Power Supply uses a push-in cable connector with 2 terminals for power and
1
terminal for hearth.
The recommended wire cross section is 2.5 mm
2
.
The fuse is located in the Power Supply socket, as well as the spare fuse.
MEMORY.-
Non volatile NOV-RAM type, to maintain stored the software configuration and the value of
the
display in case of power failure. It allows 100,000 cycles ON/OFF. The data can be
stored
for a maximum of 10 years.
RESET.-
By remote push-button using the connector of 5 terminals on the rear part.
DECIMAL POINT
.-
Programmable by software. Contact your local distributor for additional information.
SCALE FACTOR
.-The Scale Factor can be programmed from -5.9999 to 5.9999. Factory Set-up is 1.0000.
Contact your local distributor.
4.- MODELS
4.1.- MODEL
BDF-XX-T1, TOTALIZER WITH INHIBIT FUNCTION
Pulses per Channel 1 add up. Channel 2 operates as Inhibit control.
Counter remains held during all time that the Channel 2 remains connected to 0 Vdc. and runs
free meanwhile Channel 2 is free.
4.2.- MODEL
BDF-XX-T2, TOTALIZER WITH UP/DOWN CONTROL
Pulses per Channel 1. Channel 2 operates as UP/DOWN control.
If Channel 2 is connected to 0 Vdc. then the pulses will subtract.
If Channel 2 is free then the pulses will add up.
4.3.- MODEL
BDF-XX-T3, TOTALIZER UP/DOWN WITH SEPARATE INPUTS
Pulses per Channel 1 to add up.
Pulses per Channel 2 subtract to the display.
The instrument allows that both pulses in Channel 1 and Channel 2 can be simultaneously.
4.4.- MODEL
BDF-XX-T5, TOTALIZER UP/DOWN WITH QUADRATURE CONTROL
Channel 1 serves as the count and Channel 2 serves as a quadrature control.
(See paragraph 9.7).
4.5.- MODEL
BDF-XX-T6, TOTALIZER UP/DOWN WITH QUADRATURE CONTROL
Same characteristics of the BDF- XX-T5 including multiplier by 4
4.6.- MODEL
BDF-XX-TF, RATE
Pulses per Channel 1. Do not use Channel 2.
The function of this model is to show on the display parameters by time unit, such as
RPM, mts/sec., litters/hour etc...
The minimum frequency allowable is 0.03 Hz.