OPERATION

DISPLAY PANEL

The air purifier continuously works in automatic mode; the user can select which preference they would like the purifier to use based on the location or desired 

operation of the air purifier. The purifier will operate through a minimized range of speeds, not exceeding the maximum level selected, in order to run quietly while 

cleaning the room of contaminants. Once air is cleaned, and no sensors are activated, the unit lowers to energy saving mode to reduce energy consumption and 

extend the life of the filters. 

When Normal mode is selected the Normal indicator on the control panel will be blue when the access panel is open. The purifier will operate through its full range 

of speeds in order to clean the room of contaminates as quickly as possible. Once air is cleaned, and no sensors are activated, the unit lowers to energy saving mode 

to reduce energy consumption and extend the life of the filters.

When Quiet mode is selected the Quiet indicator on the control panel will be blue when the access panel is open. The purifier will operate through a minimized range 

of speeds in order to stay as quiet as possible while cleaning the room of contaminates. Once air is cleaned, and no sensors are activated, the unit lowers to energy 

saving mode to reduce energy consumption and extend the life of the filters. 

HEPA FILTER REPLACEMENT INDICATOR

 – 

This indicator will show 

its status when the access panel is open or closed. If the light is red this indicates 

the filter needs replacing. The replacement period will vary depending on the 

filters used, hours of use, air quality, and rate of air flow. For filter replacement 

indicator descriptions see 

FILTER REPLACEMENT INDICATORS

 section. 

CARBON FILTER REPLACEMENT INDICATOR

 – 

This indicator will 

show its status when the access panel is open or closed. If the light is red this 

indicates the filter needs replacing. The replacement period will vary depending 

on the filters used, hours of use, air quality, and rate of air flow. For filter 
replacement indicator descriptions see 

FILTER REPLACEMENT INDICATORS

 section.

ACCESSORY INDICATOR

 –

 

This indicator will show its status when the 

access panel is open or closed. This indicator will only be used if an accessory filter 

is installed in the unit. If the light is red this indicates the filter needs replacing. 

The replacement period will vary depending on the filters used, hours of use, air 

quality, and rate of air flow. For filter replacement indicator descriptions see 

FILTER 

REPLACEMENT INDICATORS

 section.

AIR QUALITY SENSOR

 – 

This indicator will show its status when the 

access panel is open or closed. This indicator monitors the air quality and adjusts 

the fan speed to keep your air purified. Blue, amber, and red lights indicate the 

purity of your air. 

PlasmaTRUE™ TECHNOLOGY

 –

 This indicator will show its status when 

the access panel is open or closed. Creates an ionized field to help safely remove 

airborne pollutants. To turn on and off the PlasmaTRUE™ TECHNOLOGY, touch 

and hold the PLASMA indicator. A blue light illuminates when the PlasmaTRUE™ 

TECHNOLOGY is enabled. To disable the PlasmaTRUE™ TECHNOLOGY, press and 

hold “Plasma” indicator until light is off.

NORMAL MODE

 – 

Select this mode for restrooms, cafeterias, fitness areas, 

and other louder areas as rapid purification is initiated when the room is occupied 

and/or strong airborne contaminants are present. To select, press and hold the 

“Normal” indicator until icon illuminates. This mode monitors air quality, motion, and 

noise level to adjust the fan speed in order to keep your air purified as quickly as 

possible. The fan can reach turbo speed to clean the room in the case of high levels 

of contaminant.

QUIET MODE

 – 

This mode utilizes the 3 lowest, most quiet of the 5 fan speeds. 

Select this mode for classrooms, meeting rooms, offices, and other quieter areas as 

the unit will not run faster than the maximum set speed. To select, press and hold 

the “Quiet” indicator until icon illuminates. Continue to press and hold the indicator 

to switch between the maximum speeds in this mode. There are three different 

levels; each level represents a maximum fan speed that the unit can achieve. 

•  Level  1  =  The  lowest  speed,  the  unit  will  beep  one  time  when  this  mode  

  has been selected and the unit will not run faster than this lowest speed.
•  Level  2  =  Low  speed,  the  unit  will  beep  two  times  when  this  mode  has  

  been selected and the unit will not run faster than low speed.
•  Level 3 = Medium speed, the unit will beep three times when this mode has been  

  selected and the unit will not run faster than medium speed. 
The Quiet Mode monitors air quality, motion, and noise level to adjust the fan speed 

in order to keep the air purified as efficiently as possible while not exceeding the 

maximum speed level selected.

1

5

2

6

3

7

4

1

2

3

4

5

6

7

NOTE: after the unit is turned on the “AQ” light will flash for a few minutes while the system self-calibrates.

Summary of Contents for AeraMax Pro AM4R

Page 1: ...l appareil Ne pas jeter conserver afin de consulter les directives ult rieurement en cas de besoin Lea estas instrucciones antes del uso No las deseche cons rvelas para referencia futura AeraMax Pro A...

Page 2: ...ellowes Inc Fellowes warrants the AeraMax Pro air quality control system the Product to be free of defects in material and workmanship for the time periods as set forth below For PC units only The par...

Page 3: ...CC Rules These limits are designed to provide reasonable protection against harmful interference in an installation This equipment generates uses and can radiate radio frequency energy and if not inst...

Page 4: ...d will vary depending on the filters used hours of use air quality and rate of air flow For filter replacement indicator descriptions see FILTER REPLACEMENT INDICATORS section AIR QUALITY SENSOR This...

Page 5: ...ators Red Flashing RIGHT filter 90 full Amber Flashing LEFT filter 90 full Red Flash Pause Amber Flash Pause Right LEFT filters 90 full Red Replace RIGHT filter Amber Replace LEFT filter Red Amber Alt...

Page 6: ...e managed behind the machine Attach the adhesive cable tie to the back of the machine by removing the covering of the adhesive pad and pressing firmly Ensure the removal latch lanyard is hanging down...

Page 7: ...e n est pour purifier l air Garantie limit e Fellowes Inc Fellowes garantit que le syst me de contr le de la qualit de l air AeraMax Pro le Produit sera exempt de tout d faut de mat riaux et de main d...

Page 8: ...s limites sont con ues pour offrir une protection raisonnable contre l interf rence nocive lorsque l quipement est utilis dans une installation r sidentielle Cet quipement produit utilise et peut mett...

Page 9: ...d air Pour consulter les descriptions des indicateurs de remplacement des filtres voir la section INDICATEUR DE REMPLACEMENT DES FILTRES CAPTEUR DE QUALIT DE L AIR cet indicateur affiche son tat l ou...

Page 10: ...n 90 Clignotement en orange filtre de GAUCHE plein 90 Clignotement en rouge Pause clignotement en orange Pause filtres de DROITE et de GAUCHE pleins 90 Rouge Remplacer le filtre de DROITE Orange Rempl...

Page 11: ...ixez le serre c ble adh sif l arri re de l appareil en retirant le rev tement du tampon adh sif et en l appuyant fermement Assurez vous que la lani re du loquet de retrait pend derri re la machine et...

Page 12: ...s Inc Fellowes garantiza que el sistema de control de calidad del aire AeraMax Pro el Producto no contiene defectos de materiales ni mano de obra durante el per odo indicado a continuaci n Para unidad...

Page 13: ...me a la secci n 15 de las Normas de la FCC Dichos l mites se han dise ado para proporcionar una protecci n razonable contra la interferencia da ina en instalaciones residenciales Este equipo genera us...

Page 14: ...la calidaddelaireylaubicaci ndelaunidad Paraobtenerdescripcionesdeindicadores de reemplazo del filtro vea la secci n INDICADORES DE REEMPLAZO DEL FILTRO SENSOR DE CALIDAD DEL AIRE este indicador most...

Page 15: ...l 90 de su capacidad Flash rojo Pausa Flash mbar Pausa Filtros derecho e IZQUIERDO al 90 de su capacidad Rojo Cambiar el filtro DERECHO mbar Cambiar el filtro IZQUIERDO Rojo y mbar alternante Reemplac...

Page 16: ...detr s de la m quina Fije la brida adhesiva para cables a la parte posterior de la m quina retirando la cubierta de la almohadilla adhesiva y presionando con firmeza Aseg rese de que el cord n del pes...

Page 17: ...d Avenue Itasca Illinois 60143 1 800 955 0959 www fellowes com B r a n d s 2022 Fellowes Inc Part 412656 U S 1 800 955 0959 Canada 1 800 665 4339 Mexico 001 800 514 9057 Customer Service Support www f...

Reviews: