F-901B Reference Manual 

Page 

14

 of 

15

 

 

Warranty Information 

 
Seller's Warranty and Liability: 
  
Felix  Instruments-  Applied  Food  Science  warrants  new  equipment  of  its  own  manufacturing  against  defective 
workmanship and materials for a period of one year from date of sale. The results of ordinary wear and tear, neglect, 
misuse, accident and excessive deterioration due to corrosion from any cause are not to be considered a defect.  

Felix  Instruments’  liability  for  repairing  or  replacing  defective  parts  during  the  warranty  period  is  contingent  on 

examination  by  a  Felix  Instruments  authorized  representative.  Felix  Instruments  liability  will  not  extend  beyond 
repairing  or  replacing  parts  from  the  factory  where  they  were  originally  manufactured.  Repair  or  alteration  by  an 
unauthorized technician voids warranty.  
Material and equipment which is not manufactured by Felix Instruments are to be covered only by the warranty of its 
manufacturer. Felix Instruments will not be liable to the Buyer for loss, damage, or injury to persons or to property by 
the use of equipment manufactured by other companies.  
 
 
Buyer accepts the terms of warranty through the use of this instrument and any accessory equipment. There are no 
understandings, representations, or warranties of any kind, express, implied, statutory, or otherwise (including, but 
without limitation, the implied warranties of merchantability and fitness for a particular purpose), not expressly set 
forth herein. 
 
 
All  instrument  repairs  or  replacement  covered  under  warranty  require  a  Returned  Material  Authorization  (RMA) 
number. Please contact Felix Instruments technical support department at [email protected] to obtain 
an RMA number before shipping instrument to CID Bio-Science, Inc.  
 
Buyer is responsible for shipping charges to Felix Instruments headquarters: 
 
1554 NE 3rd Ave. 
Camas, WA 98607 
USA 
 
 
Felix Instruments is responsible for return shipping charges on repairs and/or replacement covered by warranty.  

 

Summary of Contents for F-901B

Page 1: ...July 2019 F 901B Reference Manual Version 1 4 6 15 16 1554 NE 3rd Ave Camas WA 98607 USA Phone 360 833 8835 www felixinstruments com...

Page 2: ...6 Operating modes 6 MODBUS 7 RTU RS485 Configuration 7 Pin Description 7 Absolute Maximum Rating 8 RS485 Modbus Parameters 8 F 901B MODBUS Specifications 8 Input Registers 8 Holding Registers 9 Coils...

Page 3: ...e socket If sampling via tubing make sure that the tubes are securely attached to the device before operating Use the included hydrophobic filter to prevent liquid water from entering device See Cable...

Page 4: ...m Lower Detection Limit 2 ppm Response Time T90 3 minutes Temperature Range 0 C to 50 C Pressure Range 1013mbar 10 Relative Humidity Range 15 to 90 R H non condensing Long Term Output Drift 5 per mont...

Page 5: ...CURED BEFORE POWERING UP DEVICE MAKE SURE THERE IS NO FLOW OBSTRUCTION AT INLET OUTLET BEFORE POWERING UP DEVICE USE HYDROPHOBIC FILTER DURING SAMPLING TO PROTECT THE SENSOR FROM CONDENSATION Waterpro...

Page 6: ...ts not supplied Part number Description Manufacture 767KS12 DC Power Plug Sealed IP68 Switchcraft 630125673867 Patch Cable Cap IP67 water and dust protection InstallerParts Lock Ring 12VDC GND Plug ha...

Page 7: ...cycle for 30 seconds The whole routine will then repeat after some idle time Final sensor readings are updated at the end of sampling cycle and remain the same until the next update see TRIGGER_INTEV...

Page 8: ...n Pin Name Type Description 1 3 3V Reference potential 3 3V Reference Voltage 2 GND Reference potential Local device ground 3 UART_TX Digital Output Firmware update interface 4 B D Bus In Out Driver o...

Page 9: ...te Single Register o 0x0F Write Multiple Coils o 0x10 Write Multiple Registers Exception messages supported Default address o RTU 50 o TCP IP 192 168 1 50 Input Registers Mode Read only size 16 bits N...

Page 10: ...ibration parameter TRIGGER_INTERVAL 20 0 Interval between Trigger measurements in seconds Writing a value greater than 0 to this register enables Trigger mode see Operating modes Writing a 0 to this r...

Page 11: ...rite size 1 bit Name Address Default Description ZERO_C2H4 4 False Request to zero C2H4 sensor ZERO_O2 5 False Request to zero O2 ZERO_CO2 6 False Request to zero CO2 sensor ZERO_CONF 7 False Confirma...

Page 12: ...ic discharge protection Follow the below steps carefully to ensure proper sensor installations Step 2 Apply even forces at both ends to pull the Filter Tube off connectors Step 4 Pull C2H4 sensor off...

Page 13: ...ove old C2H4 sensor from connector Plug in the new C2H4 sensor then push into socket push into socket Step 7 screw new O2 sensor into socket then plug in connector Step 8 Apply force to both ends gent...

Page 14: ...on typically involves a zero baseline and a span sensitivity calibration Zero calibration commonly uses zero gas such as 100 N2 while span calibration uses target gas for calibration Below are recomme...

Page 15: ...re to be covered only by the warranty of its manufacturer Felix Instruments will not be liable to the Buyer for loss damage or injury to persons or to property by the use of equipment manufactured by...

Page 16: ...ax _____________________________ Felix Instruments Serial Number s ________________________________________ Purchase Date _____________________Purchase Price _______________________ Your opinions will...