41AP / 41AP Lite Power Voltage 

Calibration 

 

FY-41AP AFSS upgrade to firmware V1.24 or above version

FY-41AP Lite AFSS 

upgrade to firmware V1.03 or above version and work with GCS5.11 or above version can 

realize power voltage calibration function. Operation steps of power voltage calibration : 

( 1 )     Confirm that the FY-41AP / FY-41AP Lite AFSS have been upgraded to correct 

firmware, the GCS software have been update to GCS5.11 or above version.   

( 2 )     Plug the power manager to the 

“CS” power port on the FY-41 AFSS module. 

( 3 )     The AFSS module connect to the GCS software. It can connect via the USB 

data  cable  or  data  radio.  If  the  AFSS module  connect  to  the  GCS  software via  the 

USB data cable directly, please pick out the red wire (power wire) from the USB cable 

before  plug  into  the 

“UART”  port  on  the  FY-41AP  /  FY-41AP  Lite  AFSS  module, 

otherwise  the  AFSS  module  will  be  powered  on  by  USB  data  cable  and  power 

manager at the same time and it will cause a damage of the devices.   

 
 
 
 
 
 
 
 
 
 
 
 
 

( 4 )     Measure the actual voltage of the batteries, record as: V0 . 

( 5 )     Connect  the  batteries  to  the  power  manager

the  voltage  display  on  the 

GCS(BAT1) record as V1 . 

 
 
 
 
 

Formula for voltage calibration ratio

C=V0 / V1 * 100 