CAUTION:

 When installing the panel on a vertical surface, the 

mounting plate must be installed in such a way that the mount-

ing tabs are oriented in a vertical position. If the mounting tabs 

are not in this position the fixture will not be properly secured 

and could fall resulting in serious injury. 

BB

AA

AA

Installation

1  

Turning Off the Power

2  

Identifying the Wires

 

Identify the wiring: (black - line voltage, white - 

neutral and green - ground).

3  

Attaching the Mounting Plate

 

Attach the mounting plate (AA) to the junction box 

using the two #8-32 x 1 in. screws (DD).

 

Align the mounting plate in the direction you want 

the fixture to be aligned. Once the toggle bolts are 

installed, you cannot change the orientation.

4  

Positioning the Toggle Bolts

5  

Securing the Toggle Bolts

6  

Re-attaching the Mounting Plate

7  

Connecting the Fixture

 

Using the mounting plate (AA) as a guide, mark the 

position of the holes on the ceiling or wall where the 

toggle bolts will be placed.

 

Remove the mounting plate (AA) from the junction box.

 

Hook the support wire from the fixture on the 

mounting plate (AA).

 

Drill the marked locations using a 1/2 in. drill bit.

 

Remove the wings from the 3/16 in. toggle bolts (BB).

 

Insert a screw (BB) through the front of the mounting 

plate (AA) and reattach the wing to the screw (BB). 

Repeat for all toggle bolts.

CAUTION:

 Care must be taken not to have excess wires 

outside the junction box to avoid pinching wires. This may 

cause a short and could lead to a potential hazard. 

 

Feed the junction box wires through the center of 

the mounting plate (AA) hole.

 

Re-attach the mounting plate (AA) by inserting the 

toggle bolts (BB) into the drilled holes.

 

Once the wings (BB) are through and expanded, 

pull the toggle bolts (BB) downward to engage and 

tighten.

Line voltage

AA

AA

DD

DD

Ground

Neutral

 

Turn the power OFF at the switch and 

fusebox or the circuit breaker.

Summary of Contents for FP1X2/6WY/NK

Page 1: ...USE AND CARE GUIDE 1X2 LED FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURES FP1X2 6WY NK Questions problems missing parts Before returning to store visit feit com help for further assistance ...

Page 2: ...nto an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Supplier s Declaration of Conformity 47 CFR 2 1077 Compliance Information Responsible Party Feit Electric Company 4901 Greg...

Page 3: ...3 WWW FEIT COM Pre Installation Part Description Quantity AA Mounting Plate 8 07 in x 9 9 in x 0 47 in 1 BB 3 16 in Bolts 4 CC Wire Nuts 3 DD Screws 8 32 x 1 in 2 EE LED Flat Panel 1 ...

Page 4: ...Plate 7 Connecting the Fixture Using the mounting plate AA as a guide mark the position of the holes on the ceiling or wall where the toggle bolts will be placed Remove the mounting plate AA from the junction box Hook the support wire from the fixture on the mounting plate AA Drill the marked locations using a 1 2 in drill bit Remove the wings from the 3 16 in toggle bolts BB Insert a screw BB thr...

Page 5: ... hanging screw 10 Attaching the Fixture Feed the junction box and fixture wires through the mounting bracket plate s center hole Raise the fixture to the direction of the arrow on the swing arm 11 Securing the Fixture Once the fixture has been raised and is flush to the ceiling lock the fixture by moving it towards the opposite direction it was raised NOTE Before attaching the fixture select the p...

Page 6: ...an be changed from 3000K 3500K 4000K 5000K and 6500K with your existing light switch 7 To change color temperatures using your existing light switch A Set the slide switch on the back of the fixture to SWITCH B Toggle your light switch ON and OFF within 0 5 3 seconds to cycle though the 5 different color temperatures C If the fixture is left OFF for over 10 seconds then turned ON the fixture will ...

Page 7: ...Questions problems missing parts Before returning to store visit feit com help for further assistance FEIT ELECTRIC COMPANY PICO RIVERA CA www feit com ...