In case of changing power cable dismantle the cord ends max. 8 (+1) mm. Because of the bigger
wire cross section on the 110 V / 120 V versions the power cables are assembled with core cable ends.
The crimping of the core cable ends must be done as a trapeze crimping, to guarantee a safety
and durable clamping.
It‘s recommended, esspecially on 110 V and 120 V machines, to use the preassembled original cables.
Even on 220 V
– machines a cable with core cable ends can be used, as described before,
but it‘s not necessary.
8 (+1) mm
220 V - Version
110 V /120 V - Version
0. Repair informationen,
Change of power cable 220 V and 110 V / 120 V versions