6
en
–
Arsenic, chromium and other wood pre-
servatives;
–
Materials for pesticide treatment on boat
and ship hulls;
–
Stainless steel dust, metal dust and non-
ferrous metal dust;
To minimize the unwanted intake of these
materials:
–
Use dust extraction matched appropri-
ately for the developing dust.
–
Use personal protective equipment, such
as a P2 filter-class dust protection mask.
–
Provide for good ventilation of the work-
place.
The risk from inhaling dusts depends on
how often these materials are worked.
Materials containing asbestos may only be
worked on by specialists.
Wood and light-metal dust
can cause spontaneous com-
bustion or explosions.
Hot mixtures of sanding dust and paint/var-
nish residuals or other chemical materials in
the filter bag or the vac filter can self-ignite
under unfavourable conditions, such as
sparking from sanding metal, continuous
sunlight or high ambient temperatures. To
prevent this:
–
Avoid overheating the material being
sanded and the power tool.
–
Empty the dust collector/container rou-
tinely.
–
Observe the material manufacturer’s
working instructions.
–
Observe the relevant regulations for the
materials being worked.
Emission values for sound
(Two-figure – specifications as per ISO 4871)
CAUTION
Sound emission
JCM 200 QX
JCM 200 U JCM 200 auto
JCM 256 U
A-weighted emission pressure
power level measured at the work-
place
L
pA
(re 20 μPa), in decibels
81.2
81.2
81.2
81.6
Measuring uncertainty
K
pA
,
in decibels
5
5
5
5
Measured A-weighted sound
power level
L
wA
(re 1 pW),
in decibels
93.1
93.1
93.1
92.6
Measuring uncertainty
K
wA
,
in decibels
5
5
5
5
C-weighted peak sound pressure
level measured at the workplace
L
pCpeak
, in decibels
96.2
96.2
96.2
95.2
Measuring uncertainty
K
pCpeak
,
in decibels
5
5
5
5
Mean vibrational value
(core drilling)
–
m/s
2
–
ft/s
2
< 2.5
8.3
< 2.5
8.3
< 2.5
8.3
< 2.5
8.3
Measuring uncertainty
K
, in
–
m/s
2
–
ft/s
2
1.5
4.9
1.5
4.9
1.5
4.9
1.5
4.9
REMARK: The sum of the measured emission value and respective measuring inaccuracy
represents the upper limit of the values that can occur during measuring.
Wear hearing protection!
Measured values determined in accordance with the corresponding product standard.
Summary of Contents for JCM 200QX
Page 1: ...JCM 200 QX 7 270 7 273 JCM 200 U 7 270 7 273 JCM 200 auto 7 270 7 273 JCM 256 U 7 270 7 273...
Page 2: ...2 Instruction Manual Mode d emploi Instrucciones de uso en 3 fr 27 es 52...
Page 15: ...15 en Mounting the coolant hose figure 7 Connect the coolant hose...
Page 65: ...65 es Montaje de la manguera de refrige rante Figura 7 Conecte la manguera de refrigerante...