Assembly instructions.
Before mounting or replacing cutting tool or accessories, pull the power plug.
This preventive safety measure rules out the danger of injuries through acci-
dental starting of the power tool.
For all work or when changing application tools, always wear protective gloves.
Danger of injury from the sharp edges of the application tools. Application
tools can become very hot while working. Danger of burns!
Changing the tool (FMT250SL (**))
(figure 2).
The application tool can be offset in 30° steps
and fastened in the most favorable working
position.
Unscrew the clamping screw.
Clean the tool holder, the application tool and
the clamping screw.
Insert the application tool at the desired
working position. Pay attention that the appli-
cation tool is not seated uneven in the tool
holder.
Screw the clamping screw in to the stop.
WARNING
CAUTION
3.
4.
4.
4.
5.
5.
5.
1.
2.
Fig. 2
Tool holder
Clamping screw