8
en
Hand/arm vibrations.
While working with this
power tool, hand/arm vibra-
tions occur.
These can lead to health impair-
ments.
The vibration emission value
during actual use of the
power tool can differ from the declared
value depending on the ways in which the
tool is used.
It is necessary to identify
safety measures to protect
the operator that are based on an estimation
of exposure in the actual conditions of use.
The vibration emission level given in this
information sheet has been measured in
accordance with a standardized test given in
EN 62841 and may be used to compare one
tool with another. It may be used for a pre-
liminary assessment of the vibrational
impact.
The declared vibration emission level repre-
sents the main applications of the power
tool. However, if the power tool is used for
other applications with different accessories
or poorly maintained, the vibration emission
may differ. This may significantly increase
the vibrational impact over the total work-
ing period.
An estimation of the level of exposure to
vibration should also take into account the
times when the tool is switched off or when
it is running but not actually doing the job.
This may significantly reduce the vibrational
load over the total working period.
Identify additional safety measures to pro-
tect the operator from the effects of vibra-
tion such as: Maintain the power tool and
the accessories, keep the hands warm, orga-
nization of work patterns.
Emission values for sound and vibration
(Two-figure – specifications as per ISO 4871)
WARNING
WARNING
WARNING
Sound emission
AMM700MAX AS (**)
A-weighted emission pressure power level measured at the work-
place
L
pA
(re 20 μPa), in decibels
76.0
Measuring uncertainty
K
pA
, in decibels
3.0
Measured A-weighted sound power level
L
wA
(re 1 pW),
in decibels
84.0
Measuring uncertainty
K
wA
, in decibels
3.0
C-weighted peak sound pressure level measured at the workplace
L
pCpeak
, in decibels
88.4
Measuring uncertainty
K
pCpeak
, in decibels
3.0
REMARK: The sum of the measured emission value and respective measuring inaccuracy
represents the upper limit of the values that can occur during measuring.
Wear hearing protection!
Measured values determined in accordance with the corresponding product standard.