Display and Operation
4.1 Display
elements
The front panel of the detector contains 4 green LEDs for indicating the respective loop state.
LED behavior in normal operation:
LED
Description
off
Loop free
on
Loop busy or direction pulse
flashes slowly
Frequency calibration running
flashes rapidly
Loop fault (break or short)
flashes in pairs
automatic evaluation of amplitude factor in process
Chain
Synchronization indicator in 8s rhythm
4.2 (M)ode
button
The following functions can be activated by pressing the M-key on the front panel.
M-key
LED display in
binary code
Function
1x short
Uses LEDs 1-4 to display the hardware address set with DIP
switches 1-4.
1x long
Generates a hardware reset
and before that displays the set hardware address
1x short, 1x long
Generates a hardware reset
2x short, 1x long
Polls the Master (
) / Slave (
)
...
6x short, 1x long
Resets to factory default settings
The number of short presses of the button is indicated on the LEDs in binary code – left 2
3
, right 2
0
For hardware address ‚0’ the flashing sequence
/
is output.
The transition between long and short button depression is indicated after 1s by rapid flashing of all LEDs.