operating instructions
VEK FG2-1
20
12/99
FEIG ELECTRONIC GmbH
Detector responds even if loop is not covered
Possible reasons
Measures
Couplings caused by
insufficient frequency
separation
For multiplex detectors (VEK M...), frequency separation is not necessary for loops of one
detector.
Remedy: re-adjust loop frequencies and check with diagnostic device VEK FG2.
Couplings caused by
insufficient distance
between neighbouring
loops
There is no minimum distance between the loops of one detector for multiplex detectors (VEK
M...)
Remedye: Install loops with a greater distance in between
Interferences at the loop Verification: check fluctuations in
mode with the helo of diagnostic device VEK FG2. They must
not
exceed 2 increments.
Remedy: - choose another frequency level.
-
Use of an 8-loop makes the loop more insensitive to interferences.
Note: compared to square loops, 8-loops reduce the responsiveness of the system!
Interferences at the loop
feeder
Verification: check fluctuations in
position with the help of diagnostic device VEK FG2 .
- do not install the loop feeder together with other live leads in one cable pit.
Interferences at the
detector
Verification: check fluctuations in the
position witht the help of diagnostic device VEK FG2. They
The detector must not align automatically when switching loads (e.g. barrier motor).
Remedy: - connect the detector’s supply main to another phase.
Interferences caused by
compensating current in
the armouring or other
metal parts
Verification: use the diagnostic device VEK FG2, position
detuning
, to check frequency stability.
Fluctuations must not exceed 2 increments.
Remedy: choose the greatest possible distance between loops and armouring. The greater the distance
between armouring and loops, the lesser the influence on the loop.
In some unfavourable cases, the armouring has to be spared in the loop area.
Insufficient mechanical
loop solidity
Verification: tap the surface above the loop with a beam and observe diagnostic device VEK FG2 in
position with regard to possible frequency jumping or permanent detuning.
changes in the loop geometry may cause positive as well as negative detuning of the detector.
Metallic objects in loop
area
Verification: use diagnostic device VEK FG2 in
position to check frequency fluctuations and
-jumps caused by movements of the metallic object.
Note:
If metallic objects (e.g. manhole covers, grates, loose gates etc.) are surrounded by the loop,
Remedy: - re-install loop, so that the metallic object is now outside the loop field.
- replace the metallic object by a non-metallic one.
- prevent movements of the metallic object.