background image

OBID i-

scan

® 

 

MONTAGE / INSTALLATION 

ID ISC.PRH102-B 

 

FEIG ELECTRONIC GmbH 

 

M91100-2de-ID-B 

 

Technische Daten 

Technical Data 

Gehäuse / housing 

Kunststoff ABS / Plastic ABS 

Gewicht / weight 

320 g (ohne Batterien / without batteries) 

Schutzart / protection class 

IP 30 

Spannungsversorgung / Supply voltage 

4 aufladbare Batterien / 4 rechargeable AA batteries 

Leistungsaufnahme / power consumption 

max. 2,5 W / VA 

Betriebsfrequenz / Operating frequency 

13,56 MHz 

RF-Sendeleistung / RF- transmitting power 

200 mW 

 2 dB 

Antenne / Antenna 

1 x integrated HF antenna 

Unterstützte Transponder / Supported Transponder  

ISO 15693 

Schnittstellen / Interfaces 

Serial Port Profile 

Temperaturbereich / Temperature range 

  Betrieb / Operation 

  Lagerung / Storage 

 

0 °C to +50 °C 
-20 °C to +70 °C 

relative Luftfeuchte / Relative air humidity 

 

95 %  (nicht betauend / non-condensing) 

 

Die Funkanlage entspricht, bei bestimmungsgemäßer Ver-
wendung den grundlegenden Anforderungen des Artikels 3 
und den übrigen einschlägigen Bestimmungen der R&TTE 
Richtlinie 1999/5/EG vom März 99. 

Equipment Classification gemäß  

ETSI EN 301 489: Class 2 

When properly used this radio equipment conforms to the 
essential  requirements  of  Article  3  and  the  other  relevant 
provisions of the R&TTE Directive 1999/5/EC of March 99. 

 

Equipment Classification according to  

ETSI EN 301 489: Class 2 

 

FCC ID: PJMPRH102

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) this device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that may cause undesired operation. 

NOTICE: 

Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the 
FCC authorization to operate this equipment.

 

 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of 
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential 
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in ac-
cordance with the instructions, may cause harmful interference to radio communications. However, there is no guaran-
tee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio 
or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures: 
-- Reorient or relocate the receiving antenna. 
-- Increase the separation between the equipment and receiver. 
-- Connect the equipment into an outlet on a circuit different from that to  
    which the receiver is connected. 
-- Consult the dealer or an experienced radio/TV technician for help. 

 

Summary of Contents for OBID i-scan ID ISC.PRH102-B

Page 1: ... über die integrierte Schnittstelle Thank you for deciding to purchase the ID ISC PRH102 B The ID ISC PRH102 B is a device for contactless data exchange with common Transponder according ISO 15693 To this it has an integrated antenna The connection to a computer or other equipment is car ried out via the integrated interface Weiterführende Informationen und Software kön nen unter www feig de herun...

Page 2: ...echargeable AA batteries 800mAh up to 7200 mAh Zubehör Ladegerät Accessory Charger 2650 000 00 ID CHA NiMH A Hinweis Note Aufladbare Batterien und Ladegerät sind nicht im Lieferumfang enthalten Es dürfen nur Nickel Cadmium NiCd oder Ni ckel Metallhybrid NiMH Batterien verwendet werden Rechargeable batteries and battery charger are not included in the scope of delivery Use only Nickel Cadmium NiCd ...

Page 3: ...D PJMPRH102 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTICE Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC au...

Page 4: ...cm 9 inch between antenna and the human body must be maintained The operation manual should be conveniently kept available at all times for each user Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire electric shocks or injuries Such unauthorized measures shall exclude any liability by the manufacturer T...

Reviews: