background image

MONTAGE

INSTALLATION

public (B)

2006-05-30

M41200-2de-ID-B.doc

OBID i-scan

®

ID ISC.LRMU1000

ID ISC.LRU1000-M

(deutsch / english)

Summary of Contents for OBID i-scan ID ISC.LRMU1000

Page 1: ...MONTAGE INSTALLATION public B 2006 05 30 M41200 2de ID B doc OBID i scan ID ISC LRMU1000 ID ISC LRU1000 M deutsch english...

Page 2: ...OBID i scan Montage Installation ID ISC LR M U1000 FEIG ELECTRONIC GmbH Seite 2 von 52 M41200 2de ID B doc D E U T S C H deutsche Version ab Seite 3 english version from page 28 E N G L I S H...

Page 3: ...tems welches die in diesem Dokument be schriebenen Ger te enth lt FEIG ELECTRONIC weist ausdr cklich darauf hin dass die in diesem Dokument beschriebenen Ger te nicht f r den Einsatz mit oder in mediz...

Page 4: ...men 9 2 5 Antennenanschluss 10 2 6 Versorgungsspannung 10 2 7 Eing nge Ausg nge 11 2 7 1 Optokoppler 11 2 7 2 Relais 13 2 7 3 Readersynchronisation 14 2 8 Anschluss externer Diagnose LEDs 15 2 9 Schni...

Page 5: ...OBID i scan Montage Installation ID ISC LRU1000 FEIG ELECTRONIC GmbH Seite 5 von 52 M41200 2de ID B doc D E U T S C H 5 Funkzulassungen 24 5 1 Europa CE 24 5 2 USA FCC 24 6 Technische Daten 25...

Page 6: ...die Gew hrleistungsbestimmungen des Herstellers in der zum Zeitpunkt des Kaufs g ltigen Fassung F r eine ungeeignete falsche manuelle oder automatische Ein stellung von Parametern f r ein Ger t bzw u...

Page 7: ...Datentr gern sogenannten Smart Labels mit einer Betriebsfrequenz im UHF Bereich entwickelt 2 2 Verf gbare Readertypen Folgende Readermodule sind z Z verf gbar Readermodultyp Beschreibung ID ISC LRMU1...

Page 8: ...LR M U1000 FEIG ELECTRONIC GmbH Seite 8 von 52 M41200 2de ID B doc D E U T S C H 2 3 Montage Zur Befestigung des Readers befinden sich auf der Montageplatte schraffiert vier Durchbr che Bild 2 1 Reade...

Page 9: ...ite 9 von 52 M41200 2de ID B doc D E U T S C H 2 4 Anschlussklemmen Bild 2 2 Anschlussklemmen des Readers J1 J2 J12 V6 X14 T1 T2 S1 J20 X13 X11 X9 X5 GND A B Y Z O C O E IN IN GND A B Y Z GND RxD TxD...

Page 10: ...kers Klemme Beschreibung X1 X2 X3 X4 Anschluss der externen Antennen Eingangsimpedanz 50 Tabelle 2 2 Anschluss der externen Antenne 2 6 Versorgungsspannung Die Versorgungsspannung von 15 bis 24 VDC is...

Page 11: ...ste X6 sind galvanisch von der Reader Elektronik getrennt und m s sen daher mit einer externen Spannung versorgt werden Klemme Kurzzeichen Beschreibung 1 O C Kollektor Ausgang 1 2 O E Emitter Ausgang...

Page 12: ...ohmscher Lasten vorgesehen Optokopplereingang X6 3 4 Die Eingangs LED des Optokopplers ist intern mit einem Serienwiderstand von 500 beschaltet Bei Versorgungsspannungen gr er 10V muss der Eingangsst...

Page 13: ...Arbeitskontakt 2 NC ffner 3 NO Schlie er Tabelle 2 6 Pinbelegung Relaisausgang Hinweise Der Relaisausgang ist f r max 24 V DC 2 A ausgelegt Der Relaisausgang ist nur zum Schalten ohmscher Lasten vorg...

Page 14: ...onisation Mit der Readersynchronisation k nnen verschiedene Aktionen der Reader synchronisiert werden Klemme Kurzzeichen Beschreibung 1 GND GND 2 A Eingang 3 B Eingang 4 Y Ausgang 5 Z Ausgang Tabelle...

Page 15: ...icht interner LED V1 2 V2 Anode ext Funktion entspricht interner LED V2 3 V3 Anode ext Funktion entspricht interner LED V3 4 V4 Anode ext Funktion entspricht interner LED V4 5 V5 Anode ext Funktion en...

Page 16: ...e Der Anschluss der RS232 Schnittstelle erfolgt ber X8 Die bertragungsparameter k nnen per Softwareprotokoll konfiguriert werden Anschlussbelegung X8 RS232 Schnittstelle Klemme Kurzzeichen Beschreibun...

Page 17: ...Schnittstellenkonfiguration mittels Jumper Der Anschluss der RS4xx Schnittstelle erfolgt ber X7 Anschlussbelegung X7 RS485 RS422 Schnittstelle Klemme Kurzzeichen Beschreibung 1 GND RS485 RS422 GND 2...

Page 18: ...bel der Kategorie 5 verwendet werden Dies garan tiert einen problemlosen Betrieb bei 10Mbps oder 100Mbps Anschlussbelegung X8 Netzwerk Schnittstelle Klemme Kurzzeichen Beschreibung 1 TX Transmit Data...

Page 19: ...1 nach dem Reset im Anschlu an ein Software Update Blinkt abwechselnd mit V1 falls nach einem Reset ein Daten fehler beim Lesen der Parameter auftrat LED V3 gelb Diagnose 2 Host Kommunikation Signalis...

Page 20: ...von 52 M41200 2de ID B doc D E U T S C H 3 2 Taster Schalter Kurzzeichen Beschreibung T1 Reset Taster RF Controller T2 Reset Taster ACC S1 Reserviert T1 Durch bet tigen von T1 wird am RF Controller ei...

Page 21: ...onfiguration der RS485 RS422 Schnitstelle Es k nnen die eventuell ben tigten Abschlusswiderst nde mit den Jumpern J1 bis J6 zugeschaltet werden Jumper Geschlossen offen J1 Pull Up an RS4xx B ohne Pull...

Page 22: ...22 Z J4 500 RS422 A Bild 4 1 Jumper der RS485 Schnittstelle Bild 4 2 Jumper der RS422 Schnittstelle Bild 4 3 Jumper der RS485 RS422 Schnittstelle Tabelle 4 3 zeigt die Standardkonfiguration der Jumper...

Page 23: ...Reader werksseitig die Adresse 0 eingestellt haben m ssen sie nacheinander ange schlossen und konfiguriert werden 4 1 2 Netzwerkanschluss LAN Vorraussetzung f r den Einsatz des TCP IP Protokolls ist...

Page 24: ...implemented Italy max 25 mW e r p Slovak Republic max 10 mW e r p 5 2 USA FCC FCC ID PJMLRU1000 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions...

Page 25: ...Hz FCC CFR 47 Part 15 247 Sendeleistung 100 mW 3 W 100 mW Step Software 4 W EIRP FCC CFR 47 Part 15 247 2 W ERP EN 302 208 0 5Watt ERP EN 300 220 Modulationsgrad 20 40 und 100 per Software einstellbar...

Page 26: ...eber optisch 6 LEDs zur Diagnose des Betriebszustandes Multi Reader Betrieb Synchronisation der Luftprotokolle durch Ver wendung der Reader Synchronisation Umgebungsbedingungen Temperaturbereich Betri...

Page 27: ......

Page 28: ...the subject of this document FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability sui...

Page 29: ...nals 34 2 5 Antenna connection 35 2 6 Supply voltage 36 2 7 Inputs Outputs 37 2 7 1 Optocouplers 37 2 7 2 Relay 39 2 7 3 Reader synchronization 40 2 8 External diagnostic LED connections 41 2 9 Interf...

Page 30: ...OBID i scan Installation ID ISC LRU1000 FEIG ELECTRONIC GmbH Page 30 of 52 M41200 2de ID B doc E N G L I S H 5 Radio Approvals 50 5 1 Europe CE 50 5 2 USA FCC 50 6 Technical Data 51...

Page 31: ...ptions of the manufacturer in the issue valid at the time of purchase are valid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual...

Page 32: ...ive data carriers so called Smart Labels using an operating frequency in the UHF range 2 2 Available Reader types The following Readers are currently available Reader type Description ID ISC LRMU1000...

Page 33: ...C LRU1000 FEIG ELECTRONIC GmbH Page 33 of 52 M41200 2de ID B doc E N G L I S H 2 3 Installation To mount the reader there are four drilled holes in the mounting plate hatched Fig 2 1 Reader witch moun...

Page 34: ...GmbH Page 34 of 52 M41200 2de ID B doc E N G L I S H 2 4 Terminals Fig 2 2 Reader terminals J1 J2 J12 V6 X14 T1 T2 S1 J20 X13 X11 X9 X5 GND A B Y Z O C O E IN IN GND A B Y Z GND RxD TxD X12 RF Cont AC...

Page 35: ...connection The external antenna is connected on the analog circuit board The maximum tightening torque for the SMA sockets is 0 45 Nm Caution Exceeding the tightening torque will destroy the plug Ter...

Page 36: ...upply voltage of 15 to 24 VDC is connected to Terminal X13 Terminal Abbreviation Description X13 Pin 1 VDC Vcc supply voltage X13 Pin 2 GND Ground supply voltage Table 2 3 Pinouts for supply voltage F...

Page 37: ...n Terminal X6 are galvanically isolated from the Reader electronics and must therefore be externally supplied Terminal Abbreviation Description 1 O C Collector Output 1 2 O E Emitter Output 1 3 IN Inp...

Page 38: ...output is intended for switching resistive loads only Optocoupler input X6 3 4 The input LED associated with the optocoupler is connected internally to a series resistor of 500 For supply voltages of...

Page 39: ...king contact 2 NC Normally closed 3 NO Normally open Table 2 6 Relay output pinouts Notes The relay output is configured for max 24 V DC 2 A The relay output is intended for switching resistive loads...

Page 40: ...eader synchronization Reader synchronization can be used to synchronize various Reader actions Terminal Abbreviation Description 1 GND GND 2 A Input 3 B Input 4 Y Output 5 Z Output Table 2 7 Reader sy...

Page 41: ...1 V1 Anode ext Function same as internal LED V1 2 V2 Anode ext Function same as internal LED V2 3 V3 Anode ext Function same as internal LED V3 4 V4 Anode ext Function same as internal LED V4 5 V5 An...

Page 42: ...interface The RS232 interface is connected on X8 The transmission parameters can be configured by means of software protocol Pin configuration X8 RS232 interface Terminal Abbreviation Description 1 GN...

Page 43: ...tion Interface configuration The RS485 RS422 interface is connected on X7 Pin configuration X7 RS485 RS422 interface Terminal Abbreviation Description 1 GND RS485 RS422 GND 2 A RS485 RS422 A 3 B RS485...

Page 44: ...tructured cabling Cat 5 cables should be used This ensure reliable operation at 10Mbps or 100Mbps Pin configuration for X8 network interface Terminal Abbreviation Description 1 TX Transmit Data 2 TX T...

Page 45: ...y with V1 after a reset following a software update Flashes alternately with V1 in case of a data error when reading the parameters after a reset LED V3 yellow Diagnostic 2 Host communication Short fl...

Page 46: ...G ELECTRONIC GmbH Page 46 of 52 M41200 2de ID B doc E N G L I S H 3 2 Buttons Switches Abbreviation Description T1 RF Controller reset button T2 ACC reset button S1 Reserved T1 Pressing T1 resets the...

Page 47: ...RS485 RS422 port Any termination resistors needed can be enabled using jumpers J1 through J6 Jumper Closed Open J1 Pull Up on RS4xx B without Pull Up on RS4xx B J2 Pull Down on RS4xx A without Pull Do...

Page 48: ...J2 J3 J1 J6 J5 RS422 Z J4 500 RS422 A Fig 4 1 RS485 interface jumpers Fig 4 2 RS422 interface jumpers Fig 4 3 RS485 RS422 interface jumpers Tabelle 4 3 shows the standard configuration of jumpers J9 t...

Page 49: ...eader Note Since all Readers are factory set with address 0 they must be connected and configured one after the other 4 1 2 Network connection LAN The prerequisite for using TCP IP protocol is that ea...

Page 50: ...aly max 25 mW e r p Slovak Republic max 10 mW e r p 5 2 USA FCC FCC ID PJMLRU1000 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device...

Page 51: ...z FCC CFR 47 Part 15 247 Transmitting power 100 mW 3 W 100 mW Step Software 4 W EIRP FCC CFR 47 Part 15 247 2 W ERP EN 302 208 0 5 W ERP EN 300 220 Modulation 20 40 and 100 software configurable Recei...

Page 52: ...M4222 Optical indicators 6 LEDs for operating status diagnostics Multi Reader operation Synchronization of the air protocols using Reader synchronization Ambient Temperature range Operating Storage 25...

Reviews: