TU-ST:
ANT-C
reserved
VAL-ST
TU-ST C2
TU-ST C1
7
6
5
4
3
2
1
0
ANT-C: Antenna-Switch
0
⇒
ON
1
⇒
OFF (Circuit closed by jumper)
VAL-ST:
Value-Status of C1 and C2
0
⇒
OK
≠
0
⇒
Capacity out of Range
TU-ST C2:
Tuning-Status C2
TU-ST C1:
Tuning-Status C1
TU-ST C1/C2: 00
⇒
OK
01
⇒
Warning
10
⇒
Tuning necessary
3.2.5. [0xC4]: Set Outputs
This protocol is used to controll the outputs OUT1-3.
Host
→
Tuner
CMD
Data
[0xC4]
Tuner-Adr
OUT
0x02
8 bits
0xFE
8 bits
8 bits
Host
←
Tuner
Data
STATUS
0x00
8 bits
OUT:
reserved
OUT3
OUT2
OUT1
7
6
5
4
3
2
1
0
OUT1-3:
0
⇒
output OFF
1
⇒
output ON
It is possible to activate maximal two outputs at the same time or else the protocoll will be rejected
and acknowledged with STATUS 0x11 (Parameter Range Error).
1
see
3.1. System Description of the Antenna Tuner
2
see
APPENDIX A: Index STATUS