![Feig Electronic OBID i-scan ID ISC.ANT.MUX Manual Download Page 13](http://html1.mh-extra.com/html/feig-electronic/obid-i-scan-id-isc-ant-mux/obid-i-scan-id-isc-ant-mux_manual_3898673013.webp)
OBID i-scan
®
Manual
Communication FU
FEIG ELECTRONIC GmbH
Page 13 of 27
H30701-3e-ID-B
2.2.2. [0xDE]: CPU-Reset
This protocol is used to perform a CPU reset on the multiplexer.
Host
→
MUX
CMD
Data
[0xDE]
MUX-Adr
0x02
8 bits
0xFE
8 bits
Host
←
MUX
Data
STATUS
0x00
8 bits
2.2.3. [0xDD]: Select Channel
This protocol is used to set the output channel OUT1-8 on the multiplexer.
Host
→
MUX
CMD
Data
[0xDD]
MUX-Adr
OutCh1
OutCh2
0x02
8 bits
0xFE
8 bits
8 bits
8 bits
Host
←
MUX
Data
STATUS
0x00
8 bits
OutCh1:
Output Channel for IN1:
0x00 to 0x08
OutCh2:
Output Channel for IN2:
0x00 to 0x08
Settings for the individual channels greater than 0x08 or the same setting for both channels are
rejected and acknowledged with STATUS 0x11 (Parameter Range Error).
A setting of 0x00 overwrites the current channel setting.
1
see
2.1.4. Multiplexer Address Setting
2
see
APPENDIX A: Index STATUS
3
see
2.1.4. Multiplexer Address Setting
4
see
APPENDIX A: Index STATUS