Feig Electronic OBID classic-pro ID CPR.03.20-CD Manual Download Page 8

OBID

®  

classic-pro

Manual

ID CPR.03.20-CD

FEIG ELECTRONIC GmbH

Page 8 of 40

H60100-5e-ID-B.doc

2.2. 

Applicable Standards

RF approval

  Europe

  USA

EN 300 330 

FCC  47 CFR Part 15

EMC

EN 301 489

Safety

  Low Voltage

  Human Exposure

EN 60950

EN 50364

2.3. 

Approval

When properly used this radio equipment conforms to the essential requirements of Article 3 and
the other relevant provisions of the R&TTE Directive 1999/5/EC of March 99.

Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489: Class 2

FCC ID: PJMCPR03

This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.

Unauthorized modifications may void the authority granted under Federal communica-
tions Commission Rules permitting the operation of this device.

Summary of Contents for OBID classic-pro ID CPR.03.20-CD

Page 1: ...MANUAL final confidential 2008 09 23 H60100 5e ID B doc OBID classic pro ID CPR 03 20 CD Multitag Reader Data Clock and RS232 TTL up from firmware version 02 00 00...

Page 2: ...his document FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in...

Page 3: ...Format 9 3 Installation 10 3 1 Mounting 10 3 2 Connection 11 3 3 Configuration Procedure 12 3 3 1 Default Configuration 12 3 3 2 Reloading the configuration 12 4 Normal Operating Mode Fehler Textmarke...

Page 4: ...Starting FEConfigCardTool 29 6 3 FEConfigCardTool Functions 30 7 Firmware update 32 7 1 Required components 32 7 2 Programming 32 7 2 1 Starting and setting up HyperTerminal 33 7 2 2 Reader synchronis...

Page 5: ...D CPR 03 20 CD can read data blocks from mifare 1 and 4 k mifare ultra light my d proximity SLE55xx and the most of ISO 15693 Transponder The ID CPR 03 20 CD is designed to be wall mounted onto flat a...

Page 6: ...fare DESfire Smart MX my d proximity SLE44R35S SLE55R etc ISO14443B e g SLE66CL ST19XR34 etc ISO15693 e g my d vicinity I Code SLI TagIT HFI STM LRI512 etc Supported Transponder read data block ISO144...

Page 7: ...OBID classic pro Manual ID CPR 03 20 CD FEIG ELECTRONIC GmbH Page 7 of 40 H60100 5e ID B doc 2 1 Dimensions 75 17 83 5 60 7 7 4 2 120...

Page 8: ...provisions of the R TTE Directive 1999 5 EC of March 99 Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489 Class 2 FCC ID PJMCPR03 This device complies with Part 15 of the FCC R...

Page 9: ...UID1 UID0 Cascade Level 1 UID Cascade Level 2 UID Cascade Level 3 UID MSB LSB Transponder according ISO 14443 B The term UID is not specified for ISO 14443 B The following 8 bytes are the reader out...

Page 10: ...The clearance to such surfaces should be at least 30 mm The distance between readers of the same design should not be less than 50 cm Before final installation the planned installation site should be...

Page 11: ...ue Hold digital input pink RS232 TTL Rx red blue RS232 TTL Tx Service and Data Output Interface grey pink N C If the power is not supplied via the controller the power supply GND must be connected to...

Page 12: ...s as follows Reads serial numbers UID from ISO 14443 Type A ISO 14443 Type B and ISO 15693 trans ponders Data output Magstripe Track II binary 80 bit format 3 3 2 Reloading the configuration 1 Switch...

Page 13: ...OBID classic pro Manual ID CPR 03 20 CD FEIG ELECTRONIC GmbH Page 13 of 40 H60100 5e ID B doc...

Page 14: ...for more then 1 5 seconds UID Length Error If the Transponder UID is shorter than configured in ID CPR 03 20 CD a length error is signalized with 2 short beeps In this case no data s are transmitted...

Page 15: ...Parity bits The reader forms an odd and an even parity bit and encapsulates the output data The even parity bit is formed for the first half of the transmitted data the odd parity bit for the second h...

Page 16: ...8 ee eeee eeee e ooo oooo oooo Output 24 Bit 1 11 1011 0010 1101 0110 1001 1 Even Parity Bit Odd Parity Bit Example 2 MSB LSB UID hex 0 2 5 8 7 B 2 D 6 9 2 1 UID bin 0000 0010 0101 1000 0111 1011 0010...

Page 17: ...Bit Code LSB MSB P 0x0 b 0 0 0 0 1 0x1 b 1 0 0 0 0 0x2 b 0 1 0 0 0 0x3 b 1 1 0 0 1 0x4 b 0 0 1 0 0 0x5 b 1 0 1 0 1 0x6 b 0 1 1 0 1 0x7 b 1 1 1 0 0 0x8 b 0 0 0 1 0 0x9 b 1 0 0 1 1 0xA b 0 1 0 1 1 0xB...

Page 18: ...OBID classic pro Manual ID CPR 03 20 CD FEIG ELECTRONIC GmbH Page 18 of 40 H60100 5e ID B doc Timing 1 0 1 0 tn ta tb CLOCK DATA CLS tv ts 0 tn 1 ms ta n tn 3 tb n tn 2 tv ts 10 12 ms...

Page 19: ...LGT 16 D_START 8 2 D 6 9 4 Output 11010 01000 10110 01101 10011 11111 00100 LRC Stop Sign D_DIGIT 4 Start Sign Decimal The data bytes are converted to their decimal equivalent max 5 bytes 13 decimal d...

Page 20: ...e data s are encoded in ASCII format The data bytes are dissected into their nibbles and transformed into the equivalent ASCII char before they are transmitted hex Raw Data Transferred hex Value ADCII...

Page 21: ...apter 2 4 UID Format In case of smaller UID length the missing most significant digits are filled with 0 Example ISO14443 A Transponder with hexadecimal UID hex 02 58 7B 2D 69 21 Output hex 0x02 0x31...

Page 22: ...T D_LGT D_DIGIT SCAN DATA DB_ADR Default 0x07 0x00 0x00 0x20 0x0A 0x00 0x00 Byte 7 8 9 10 11 12 13 Contents RFU Mifare_KEY Default 0x00 0x00 0x00 0x00 0x00 0x00 0x00 TAG_DRV Defines the enabled Transp...

Page 23: ...tripe Track II b010 Magstripe Track II decimal N A 4 3 Magstripe Track II b011 RS232 TTL ASCII binary binary 4 4 Asynchronous Interface RS232 TTL RS232 BAUD Parameter for selecting the Baudrate for RS...

Page 24: ...ATA the start conditions for D_LGT counting are dif fering according the following table ITF_OUT SCAN DATA data clock RS232 TTL UID D_START N A DATA BLOCK DB_ADR DB_ADR Depending on the selected Inter...

Page 25: ...igured transponder see parameter TAG_DRV b001 mifare standard DATA BLOCK b010 mifare ultra light DATA BLOCK b011 SLE55xx public DATA BLOCK b100 ISO 15693 DATA BLOCK NOTE If DATA BLOCK reading is selec...

Page 26: ...the identification characteristics of a valid ConfigCard and is formatted as follows Byte 1 2 3 4 Content UID_CRC C 0x43 2 0x32 UID_CRC CRC16 checksum calculated above the 8 byte Transponder UID see 5...

Page 27: ...CRC16 is equal like used in ISO15693 After the CRC calculation the one s complement has to be built Polynomial x16 x12 x5 1 CRC_POLYNOM 0x8408 Preset Value 0xFFFF CRC_PRESET 0xFFFF C Example unsigned...

Page 28: ...Port or one USB Port 6 1 Installation of FEConfiCardTool FEConfigCardTool is designed to work with the following OBID reader Reader Type Order No ISO1443A B support ISO15693 support ID CPR 02 VP AB A...

Page 29: ...rst the port USB or COM If a RS232 reader is used select the COM port on which the reader is connected and push the Detect button If FEConfig CardTool has detected the reader at the selected COM Port...

Page 30: ...n screen includes the whole functionality of FEConfigCardTool Menus Under the header line the following functions are accessible File Open Opens a XML formatted configuration file Save As Saves the cu...

Page 31: ...t a configuration parameter which is described in chapter 5 1 Configuration Parameter Please refer to this description to get detailed information about each parameter ConfigCard Description This file...

Page 32: ...LED on the reader is active during the firmware update 7 1 Required components X modem compatible terminal application e g HyperTerminal RS232 TTL converter FEIG Order No 1962 000 00 e g model 232LPT...

Page 33: ...ws operating system documenta tion for further details To start the HyperTerminal application go to Windows Start menu Programs Accessories Communications Create a new connection by entering a name e...

Page 34: ...ronisation PPPPPPPP NOTE Use capital letters only for command input 1 Start sending P characters 0x50 2 Switch on the reader s power supply while sending P characters Synchronize the PC interface to t...

Page 35: ...E WAIT A few seconds later the Start DOWNLOAD message will ask you to send the new firmware file to the reader You have approximately 2 minutes to do this During this time the characters C or appear a...

Page 36: ...OBID classic pro Manual ID CPR 03 20 CD FEIG ELECTRONIC GmbH Page 36 of 40 H60100 5e ID B doc Successful programming is acknowledged with OK...

Page 37: ...rogramming the new firmware the VERIFY command can be used to com pare the programmed firmware to the mhx file Enter the VERIFY command and press the Send button to select the mhx file again The proce...

Page 38: ...Described Firmware 02 00 00 RS232 TTL Interface is useable for transponder data output Beneath the UID also Data Blocks can be read from different Transponder ConfigCard Identifier changed from C1 to...

Page 39: ...r stored without error Control command has been executed Hex value Transponder Status 0x02 Data False CRC parity or framing error at received data 0x83 RF Communication Error Anticollision could not b...

Page 40: ...261 5 260 8 byte NXP Philips ISO 15693 0x04 I Code SLI 32 0 27 4 byte NXP Philips ISO 14443 A MF1 IC S50 mifare 1k 64 47 5 16 byte NXP Philips ISO 14443 A MF1 IC S70 mifare 4k 256 215 6 16 byte NXP Ph...

Reviews: