background image

MONTAGE

INSTALLATION

final

public (B)

2008-10-16

M80807-1de-ID-B.doc

OBID

®

 classic-pro

ID CPR.02.10-AD

ID CPR.02.10-B

(deutsch / english)

Summary of Contents for OBID classic-pro ID CPR.02.10-AD

Page 1: ...MONTAGE INSTALLATION final public B 2008 10 16 M80807 1de ID B doc OBID classic pro ID CPR 02 10 AD ID CPR 02 10 B deutsch english...

Page 2: ...OBID classic pro Montage ID CPR 02 10 AD B FEIG ELECTRONIC GmbH Seite 2 von 28 M80807 1de ID B doc D E U T S C H deutsche Version ab Seite 3 english version from page 16 E N G L I S H...

Page 3: ...diesem Dokument gemachten Installationsempfehlungen gehen von g nstigsten Rahmenbedingun gen aus FEIG ELECTRONIC GmbH bernimmt weder Gew hr f r die einwandfreie Funktion in system fremden Umgebungen n...

Page 4: ...s 8 4 1 Jumper und Schalter 9 4 2 Spannungsversorgung 9 4 3 Relais ID CPR 02 10 B 10 4 4 Digitale Eing nge 10 4 5 RS232 Schnittstelle ID CPR 02 10 AD 10 4 6 RS485 Schnittstelle ID CPR 02 10 B 11 4 6 1...

Page 5: ...ungs und sonstige Arbeiten am Ger t d rfen nur von Elektrofachkr ften mit einschl giger Ausbildung erfolgen Alle Arbeiten am Ger t und dessen Aufstellung m ssen in bereinstimmung mit den nationalen el...

Page 6: ...rden da diese Fl chen eine Reduzie rung der Lesereichweite bewirken Bei der Montage auf Metalloberfl che sollte die Montage mit dem Aufputzadapter erfol gen damit ein ausreichender Abstand zwischen Le...

Page 7: ...erteil auf der Wand verschrauben Montagerichtung TOP beachten siehe Kapitel 3 Montage Geh useoberteil gerade auf das Geh useunterteil aufstecken und einrasten Stiftleiste X1 der Leserelektronik sauber...

Page 8: ...u endurchmesser der Anschlussleitung bei Aufputzmontage 7 0 mm Empfohlene Aufbau paarverseilt TP Abbildung 6 Anschlussplatine Klemme Funktion Leiste Bezeichnung ID CPR 02 10 AD ID CPR 02 10 B Spannung...

Page 9: ...wahlweise mit 12 24 V AC oder DC versorgt werden Die Polarit t bei DC Spannungsversorgung kann frei gew hlt werden Bei der Dimensionierung des Netzteils und der Anschlussleitung ist der Spannungsabfa...

Page 10: ...t Der Anschluss erfolgt ber die Klemmen NO und COM 4 4 Digitale Eing nge Die digitalen Eing nge IN1 IN2 und IN3 d rfen nur gegen intern GND Klemme GND ge schaltet werden siehe Abbildung 8 Eine Beschal...

Page 11: ...Busbetrieb setzt einen Leitrechner mit Abschlusswiderstand und aktiver Terminierung voraus Als Leitung wird eine paarweise verseilte oder verdrillte Leitung empfohlen Host mit aktiver Terminierung ohn...

Page 12: ...Adresse DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 ON OFF OFF ON 10...

Page 13: ...2 dB RF Interface ISO14443 A ISO14443 B NFC 1 ISO15693 unterst tzte Transpondertypen z B mifare classic mini 1k 4k mifare UltraLight mifare DESfire Smart MX my d proximity SLE44R35S SLE55R JewelTM SLE...

Page 14: ...e Funkanlage entspricht bei bestimmungsgem er Verwendung den grundlegenden Anforde rungen des Artikels 3 und den brigen einschl gigen Bestimmungen der R TTE Richtlinie 1999 5 EG vom M rz 99 Equipment...

Page 15: ...1de ID B doc 5 2 Abmessungen 60 0 mm 60 0 mm 84 2 mm 84 2 mm 77 7 mm 56 8 mm 60 0 mm 28 4 mm 28 4 mm 77 7 mm Abbildung 14 Unterputzgeh use Befestigungsmasse Abbildung 15 Aufputzadapter Befestigungsmas...

Page 16: ...s given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and does not give any guaranty...

Page 17: ...8 3 Installation 19 4 Reader connection 21 4 1 Jumper and Switches 22 4 2 Power supply 22 4 3 Relay ID CPR 02 10 B 23 4 4 Digital inputs 23 4 5 RS232 Interface ID CPR 02 10 AD 23 4 6 RS485 Interface I...

Page 18: ...incorrect application of a device Repairs may only be executed by the manufacturer Installation operation and maintenance procedures should only be carried out by qualified personnel Use of the devic...

Page 19: ...faces metal grids reinforcements or metallized surfaces as these surfaces reduce the detection range of the Reader If an installation to a metal surface becomes necessary the surface adapter can be e...

Page 20: ...bottom part of casing to selected surface Take care about the mounting direction TOP see chapter 3 Installation Put the casing upper part straight onto its bottom part and snap it in see Fig 4 Insert...

Page 21: ...om part of the casing Fig 6 Connection board connector function board name ID CPR 02 10 AD ID CPR 02 10 B power supply 12 24 AC DC CLS data clock interface CLS COM NO digital input 3 relay GND interna...

Page 22: ...onnectors and The device may be supplied ei ther with 12 24 V AC or DC In case of DC supply the polarity may be chosen freely For the dimensioning of the power supply and the connecting cable the volt...

Page 23: ...ly open contact The connection is executed via the connectors NO and COM 4 4 Digital inputs The digital inputs IN1 IN2 and IN3 can only be connected to intern GND see Fig 8 Any connection to external...

Page 24: ...X2 see Fig 10 and Fig 6 To operate the bus you need a host computer with a terminating resistor and active termination A twisted paired or stranded wire is recommended without termination R A T B Read...

Page 25: ...ividual address Address DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 O...

Page 26: ...Transmitting Power 250 mW 2 dB RF Interface ISO14443 A ISO14443 B NFC 2 ISO15693 Supported Transponder e g mifare classic mini 1k 4k mifare UltraLight mifare DESfire Smart MX my d proximity SLE44R35S...

Page 27: ...urope CE When properly used this radio equipment conforms to the essential requirements of Article 3 and the other relevant provisions of the R TTE Directive 1999 5 EC of March 99 Equipment Classifica...

Page 28: ...of 28 M80807 1de ID B doc 5 2 Dimensions 60 0 mm 60 0 mm 84 2 mm 84 2 mm 77 7 mm 56 8 mm 60 0 mm 28 4 mm 28 4 mm 77 7 mm Fig 14 Concealed casing Fixing dimensions Fig 15 Surface adapter dimensions 84...

Reviews: