background image

Installation Manual ID RWA12.ABC-A / -B

FEIG ELECTRONIC GmbH

Page 27 of 28

E N G L I S H

6.  ANNEX B: Technical data

  casing

plastic (ASA)

  colour

similar to RAL 9002 (greyish white)

  dimensions ( W x H x D )

296 x 243 x 43 mm

  weight

ca. 1,2 kg

  protection class

IP 54

  power supply

12 - 24 V  AC/DC

  power consumption

max. 5 W

  temperature range

-25°C to 70°C

  relative air humidity

95 %  (non condensing)

  antenna

integrated

  data transmission with transponder

125 kHz / AM / half duplex

  supported transponders

ID CTx.A
ID DTx.B
ID DTx.C

  crypto processor

6

:

  ID RWA12.ABC-AK

  ID RWA12.ABC-BK

  signal transmitter

  1 x bicolor-LED (red, green, orange)

  1 x beeper

  semiconductor-relay

1 x make-contact

loading-capacity of contact: 24 V AC/DC  1,5 A

fuse: »miniature fuse TR 5 (T1,6 A)«

  digital inputs

  2 x configurable (feeding-wire length max. 3 m)

  interfaces:

ID RWA12.ABC-A /-AK:

ID RWA12.ABC-B /-BK:

RS232

RS485 (max. 32 devices per data bus)

  Address configuration for interface

  4-pole DIP-switch (16 addresses) or

  256 addresses per software adjustable

  EEPROM

10.000 writing cycles

                                                

6

 IMPORTANT

:

Repairs at devices with crypto-processor can only be executed if the CryptoKeys stored
in the crypto-processor correspond to the factory adjustment!

Summary of Contents for ID RWA12.ABC-A

Page 1: ...M90191 4de ID B DOC Montageanleitung Mounting Instruction midrange multijob Reader ID RWA12 ABC A AK RS232 interface ID RWA12 ABC B BK RS485 interface deutsch english ...

Page 2: ...Identifikation System OBID Seite 2 von 28 FEIG ELECTRONIC GmbH D E U T S C H deutsche Version ab Seite 3 english version from page 16 E N G L I S H ...

Page 3: ...e Zusammenstellung der Informationen in dieser Montageanleitung erfolgt nach bestem Wissen und Gewissen FEIG ELECTRONIC GmbH übernimmt keine Gewährleistung für die Richtigkeit und Vollständigkeit der gemachten Angaben Insbesondere kann FEIG ELECTRONIC GmbH nicht für Folgeschäden aufgrund fehlerhafter oder unvollständiger An gaben haftbar gemacht werden Die in diesem Handbuch gemachten Installation...

Page 4: ...schluß 8 4 1 Spannungsversorgung 9 4 2 digitale Eingänge IN1 IN2 9 4 3 Relais 9 4 4 RS485 Schnittstelle ID RWA12 ABC B BK 10 4 5 RS232 Schnittstelle ID RWA12 ABC A AK 10 5 Inbetriebnahme 11 5 1 Konfiguration mit OBID MasterCard 11 5 2 LED und Beeper Anzeigen 12 5 3 Geräteadresse Online Systeme 13 6 Anhang B Technische Daten 14 6 1 Anhang B1 Abmessungen 15 ...

Page 5: ...lung von Parametern für ein Gerät bzw ungeeignete Verwendung eines Gerätes wird keine Haftung übernommen Reparaturen dürfen nur vom Hersteller durchgeführt werden Der Benutzer ist dafür verantwortlich dass das Gerät nach den anerkannten technischen Regeln im Aufstellungsland sowie anderen regionalen gültigen Vorschriften aufgestellt und angeschlossen wird Vor dem Öffnen des Gerätes ist stets die V...

Page 6: ... x multijob midrange Reader 1 x Klarsichtscheibe 2 x Frontaufkleber 2 x Gehäuseschauben 3 5 x 25 mm 3 x Würgenippel 2 x 16 mm Loch für Leitung 5 7 mm 1 x 19 mm Loch für Leitung 7 10 mm 1 x Ersatz Miniatursicherung TR 5 T1 6 A 1 x Jumper für J150 ID RW12 ABC B 1 x Montage und Bedienungsanleitung ...

Page 7: ...allation sollte der geplante Installationsort auf seine Taug lichkeit geprüft werden Reihenfolge der Montage beachten 1 Wandmontage Montageort suchen Die Montage sollte auf einem möglichst ebenen Unter grund erfolgen Durchbrüche für Zuleitungen herzustellen und mit den beiliegenden Würge nippeln versehen Zuleitungen einziehen Gehäuseunterteil mit Untergrund verschrauben Empfohlene Schrauben 4 x 40...

Page 8: ...igitale Eingänge und Schnittstellen wird der Einsatz ab geschirmter Leitungen empfohlen Der Schirm ist an Stecker X7 anzuschließen Abbildung 1 Lage der Anschlußkemmen und Bedienelemente Stecker Bezeichnung Funktion Spannungsversorgung R A A RxD T B RS485 B RS232 TxD CLK DAT X1 GND interner GND IN1 digitaler Eingang 1 IN2 digitaler Eingang 2 GND interner GND COM X2 NO Relais Schließer S1 X7 S2 Schi...

Page 9: ...t direkt parallel mit anderen Energieversorgungs und Niederspan nungsleitungen verlegt werden 4 2 digitale Eingänge IN1 IN2 Die beiden digitalen Eingänge Stecker X2 IN1 bzw IN2 siehe Kapitel 4 Leseranschluß sind nur gegen GND an Stecker X2 zu schalten Eine Beschaltung mit Fremdspannung kann zur Zer störung des Gerätes führen IN1 IN2 GND Ub Abbildung 2 Anschluß der digitalen Eingänge 4 3 Relais Das...

Page 10: ...stallation im Einzelfall zu prüfen Der Abschlußwiderstand ist i d R nur am Busende also am letzten Gerät notwendig Durch Auf stecken des Jumpers J150 siehe Abbildung 1 Lage der Anschlußkemmen und Bedienelemente kann an ein Abschlußwiderstand von 100 Ω zwischen den Leitungen RS485 A und RS485 B akti viert werden Host Reader 1 J150 Reader 2 J150 Reader n J150 Abbildung 3 typischer Aufbau eines RS485...

Page 11: ...terCard erfolgt nach folgenden Ablauf 1 Reset an multijob Reader auslösen Danach ist der MasterCard Mode für mindestens 1 Sek aktiv Solange der MasterCard Mode aktiv ist blinken die LEDs für jeweils 200 ms rot Õ aus Õ grün Õ aus 2 Gelangt während des MasterCard Mode eine gültige OBID MasterCard in den Erfassungs bereich des multijob Readers werden die Parameter von der OBID MasterCard ausgelesen u...

Page 12: ...YSTEM ID 4 x CFG ALLOC Checksummenfehler 5 x CFG ALLOC Adressbereichsfehler ungültige CFG EE 6 x Parameter Checksummenfehler 7 x internes EEPROM fehlerhaft EE Init Mode je 520 ms rot Õ grün Checksumme eines EEPROM Parametersatzes CFG EE war fehlerhaft Diese r wurde n mit Default Wert en initialisiert Offline Mode 1 gelb blinken Keine Kommunikation multijob Poll zwischen Host und multijob Reader On...

Page 13: ...he Abbildung 1 Lage der Anschlußkemmen und Bedienelemente gemäß nachste hender Tabelle Dabei wird jeder Leser mit einer individuellen Adresse versehen Adresse DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 ON OFF OFF ON 10 OFF ON OFF ON 11 ON ON OFF ON 12 OFF OFF ON ON 13...

Page 14: ...D DTx C Kryptoprozessor 3 ID RWA12 ABC AK ID RWA12 ABC BK Signalgeber 1 x Bicolor LED rot grün orange 1 x Beeper Halbleiter Relais 1 x Schließer Kontaktbelastbarkeit 24 V AC DC 1 5 A Sicherung Miniatursicherung TR 5 T1 6 A digitale Eingänge 2 x konfigurierbar Zuleitungslänge max 3 m Schnittstellen ID RWA12 ABC A AK ID RWA12 ABC B BK RS232 RS485 max 32 Geräte pro Datenbus Adresseinstellung für Schn...

Page 15: ...Montageanleitung ID RWA12 ABC A B FEIG ELECTRONIC GmbH Seite 15 von 28 D E U T S C H 6 1 Anhang B1 Abmessungen Abbildung 5 Montageabmessungen ...

Page 16: ...s editions become void Composition of the information in this manual has been done to the best of our knowledge FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information Since despite all our efforts errors may not be completely avoided we are always grateful f...

Page 17: ...ntents 19 3 Installation 20 4 Reader connection 21 4 1 Power supply 22 4 2 Digital inputs IN1 IN2 22 4 3 Relay 22 4 4 RS485 Interface ID RWA12 ABC B BK 23 4 5 RS232 Interface ID RWA12 ABC A AK 23 5 Initiation 24 5 1 Configuration with OBID MasterCard 24 5 2 LED and beeper Signals 25 5 3 Device address Online systems 26 6 ANNEX B Technical data 27 6 1 ANNEX B1 Dimensions 28 ...

Page 18: ...proper use of the appliance Installation initiation maintenance measuring and adjustment of the appliance should only be carried out by electricians with a good knowledge of the rules for the prevention of accidents All labour that is carried out on the appliance as well as its initiation has to conform to the national as well as the local regulations The user has to make sure that the appli ance ...

Page 19: ... x multijob midrange Reader 1 x transparent pane 2 x adhesive front label 2 x casing screws flat head 3 5 x 25 mm 3 x twisting nipple 2 x 16 mm hole for wire 5 7 mm 1 x 19 mm hole for wire 7 10 mm 1 x spare miniature fuse TR 5 T1 6 A 1 x Jumper for J150 ID RW12 ABC B BK 1 x Installation and operation manual ...

Page 20: ...installation place should be tested Respect the installation order 1 Wall installation Select installation place The device should be installed on a surface as even as possible Make openings for the supply wires and provide with included twisting nipples Draw in wires Screw lower part of the casing to the surface recommended screws 4 x 40 mm button head screw or slotted pan head screw 2 Reader con...

Page 21: ...ng in wires for digital inputs and interfaces we recommend shielded wires The shield has to be connected to connector X7 Fig 1 Position of the connecting terminals and the operational control connector term function power supply R A A RxD T B RS485 B RS232 TxD CLK DAT X1 GND internal GND IN1 digital input 1 IN2 digital input 2 GND internal GND COM X2 NO relay make contact S1 X7 S2 shield ...

Page 22: ...rectly parallel to other power supply or low voltage lines 4 2 Digital inputs IN1 IN2 Both digital inputs connector X2 IN1 respectively IN2 see chapter 4 Reader connection have to be switched only opposite GND to connector X2 A supply with external voltage may cause the damage of the device IN1 IN2 GND Ub Fig 2 Connection of the digital inputs 4 3 Relay The device is provided with an electronical ...

Page 23: ...r has to be checked individually Normally the terminal resistor is necessary only at the end of the bus that means at the last device By pinning up the jumper J150 see Fig 1 Position of the connecting terminals and the operational control a terminal resistor of 100 Ω can be activated between lines RS485 A and RS485 B Host Reader 1 J150 Reader 2 J150 Reader n J150 Fig 3 typical structure of an RS48...

Page 24: ...MasterCard is performed according to the following sequence 5 Reset the multijob Reader After this the MasterCard Mode will be active for at least 1 sec While the MasterCard Mode is active the LEDs will flash for 200 ms each red Õ off Õ green Õ off 6 If a valid OBID MasterCard comes into the detection range of the multijob Reader during the MasterCard Mode the parameters are read out by the OBID M...

Page 25: ...y SYSTEM ID 9 x CFG ALLOC checksum error 10 x CFG ALLOC address area error invalid CFG EE 11 x Parameter checksum error 12 x internal EEPROM defect EE Init Mode 520 ms each red Õ green Checksum of an EEPROM parameter record CFG EE has been faulty This these has have been initialized with a default value s Offline Mode 4 yellow flashing No communication multijob Poll between host and multijob Reade...

Page 26: ...s and the operational control according to the table seen below by means of this each reader is provided with an individual address address DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 ON OFF OFF ON 10 OFF ON OFF ON 11 ON ON OFF ON 12 OFF OFF ON ON 13 ON OFF ON ON 14 OF...

Page 27: ... DTx B ID DTx C crypto processor 6 ID RWA12 ABC AK ID RWA12 ABC BK signal transmitter 1 x bicolor LED red green orange 1 x beeper semiconductor relay 1 x make contact loading capacity of contact 24 V AC DC 1 5 A fuse miniature fuse TR 5 T1 6 A digital inputs 2 x configurable feeding wire length max 3 m interfaces ID RWA12 ABC A AK ID RWA12 ABC B BK RS232 RS485 max 32 devices per data bus Address c...

Page 28: ...Identifikation System OBID Page 28 of 28 FEIG ELECTRONIC GmbH E N G L I S H 6 1 ANNEX B1 Dimensions Fig 5 Installation dimensions ...

Reviews: