![Feig Electronic ID MAX.U500i Series Quick Installation Download Page 3](http://html1.mh-extra.com/html/feig-electronic/id-max-u500i-series/id-max-u500i-series_quick-installation_3869558003.webp)
IDENTIFICATION
ID MAX.U500i
Teach-In Mode
Page 3 of 4
STEP 4
To connect the external electronics, use the potential-free relay output or the potential-free digital output,
which is galvanically isolated from the reader electronics.
REL1-NO
Normally open contact relay 1
OPTO1-OUT-E
Digital Output 1 Emitter (–)
REL1-COM
Changeover contact relay 1
OPTO1-OUT-C
Digital Output 1 Collector (+)
REL2-NO
Normally open contact relay 1
OPTO2-OUT-E
Digital Output 2 Emitter (–)
REL2-COM
Changeover contact relay 1
OPTO2-OUT-C
Digital Output 2 Collector (+)
STEP 5
The installation is finished. Close the housing of the ID MAX.U500i and tighten the two hex screws. Skip this
step if you want to use the Teach-In Mode.
Teach-In Mode
STEP 1
Open the ID MAX.U500i by loosening the two hex screws and swinging the device open.
STEP 2
Press button „T1“ twice quickly to switch to the reader’s Teach-In Mode and add transponders for vehicle
access control. The yellow status LED “Res.” is now permanently lit.
STEP 3
Hold the transponder(s) to be read in front of the internal antenna (ANT1). The blue status LED of the
internal antenna (ANT1) lights up to signal the reading of a transponder. The transponders are now
temporarily stored in the reader.
STEP 4
Press button „T1“ again twice quickly to end the Teach-In Mode. The flashing of the yellow status LED “Res.”
signals the permanent storage of the transponders read in in the reader.