IDENTIFICATION 

ID MAX.U500i 

Teach-In Mode 

 

 

 

Page 3 of 4 

 

STEP 4 

To connect the external electronics, use the potential-free relay output or the potential-free digital output, 
which is galvanically isolated from the reader electronics. 

 

REL1-NO 

Normally open contact relay 1 

 

OPTO1-OUT-E 

Digital Output 1 Emitter (–) 

REL1-COM 

Changeover contact relay 1 

 

OPTO1-OUT-C 

Digital Output 1 Collector (+) 

REL2-NO 

Normally open contact relay 1 

 

OPTO2-OUT-E 

Digital Output 2 Emitter (–) 

REL2-COM 

Changeover contact relay 1 

 

OPTO2-OUT-C 

Digital Output 2 Collector (+) 

 

 

 

STEP 5 

The installation is finished. Close the housing of the ID MAX.U500i and tighten the two hex screws. Skip this 
step if you want to use the Teach-In Mode. 

Teach-In Mode 

STEP 1 

Open the ID MAX.U500i by loosening the two hex screws and swinging the device open. 

STEP 2 

Press button „T1“ twice quickly to switch to the reader’s Teach-In Mode and add transponders for vehicle 
access control. The yellow status LED “Res.” is now permanently lit. 

STEP 3 

Hold the transponder(s) to be read in front of the internal antenna (ANT1). The blue status LED of the 
internal antenna (ANT1) lights up to signal the reading of a transponder. The transponders are now 
temporarily stored in the reader. 

STEP 4 

Press button „T1“ again twice quickly to end the Teach-In Mode. The flashing of the yellow status LED “Res.” 
signals the permanent storage of the transponders read in in the reader. 