Feig Electronic ID ISC.MU02.02 Installation Manual Download Page 19

Identification 

Installation 

ID ISC.MU02.02 

 

FEIG ELECTRONIC GmbH 

Page 19 of 22 

M91002-5e-ID-B.docx 

 

AMBIENT CONDITIONS 

 

 

 

Temperature Range 

  Operation 

  Storage 

 

-25 °C to +55 °C (-13°F to 131 °F)  
-25 °C to +85 °C (-13°F to 185 °F) 

Humidity 

5 % to 95 % non-condensing 

 

 

APPLICABLE STANDARDS 

 

 

 

Radio Regulation 

  Europe 

  USA 

  Canada 

 

EN 302 208 
FCC 47 CFR Part 15 
IC RSS-Gen, RSS-210 

EMC 

EN 301 489 

Safety 

EN 60950 

 

* Caution: Overheating of the device may result in performance losses. It is recommended to activate the RF of the reader only if there is a transponder in 
the detection range of an antenna.

 

 

Summary of Contents for ID ISC.MU02.02

Page 1: ...INSTALLATION final public B 2018 09 19 M91002 5e ID B docx ID ISC MU02 02 UHF Reader Module...

Page 2: ...ts errors may not be completely avoided we are always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not gi...

Page 3: ...er issue If bits within one byte are filled with these bit spaces are reserved for future extensions or for internal testing and manufacturing functions These bit spaces must not be changed as this ma...

Page 4: ...allation and wiring 9 3 1 Dimensions 9 3 2 Wiring Connector X2 10 3 2 1 Supply voltage 11 3 2 2 RS232 interface 11 3 2 3 Data Clock interface 12 3 2 4 Shut Down 13 3 3 USB interface 14 3 4 Antenna por...

Page 5: ...Identification Installation ID ISC MU02 02 FEIG ELECTRONIC GmbH Page 5 of 22 M91002 5e ID B docx 5 2 4 USA FCC and Canada IC approved antennas 22...

Page 6: ...alid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect applicati...

Page 7: ...z It is suitable for any application in which short and middle read ranges and small reader dimensions are required The module has 2 integrated antenna outputs for connecting 2 different 50 antennas 2...

Page 8: ...Clock 2259 000 00 ID CAB RS A Cable for RS232 and Power supply 1690 000 00 RS232 LVTTL TTL Serial Data Converter 1962 000 00 ID Net 5V Power Supply 1689 000 00 For USB Port connection ID CAB USB B Ca...

Page 9: ...U02 02 FEIG ELECTRONIC GmbH Page 9 of 22 M91002 5e ID B docx 3 Installation and wiring 3 1 Dimensions Figure 1 shows the dimensions of the ID ISC MU02 02 Reader Module in mm Figure 1 Dimensions of the...

Page 10: ...g Figure 2 Pin assignments for Terminal X2 Table 3 Pin assignments for Terminal X2 Pin Function Description 1 DAT Data line for the data clock interface 2 CLK Clock line for the data clock interface 3...

Page 11: ...Use only regulated power supplies GND Pins 4 and 9 are to be connected directly to each other on the Reader Module NOTE The reader has to be supplied by a limited power supply e g NEC Class 2 LPS powe...

Page 12: ...and DTR manually 3 2 3 Data Clock interface The length of the cable to the data clock interface should be kept as short as possible It must not exceed 3 m Table 7 Pin assignment for the Data Clock in...

Page 13: ...ut Down The ID ISC MU02 02 can be switched off with the SHDN pin pin no 6 at terminal X2 Therefor the pin has to be connected to Ground Table 8 Status table for the SHDN pin X2 Pin no 6 Operating stat...

Page 14: ...und 3 D USB D PLUS 4 D USB D MINUS 5 VCC 5 V power supply The power supply follows though the USB interface Bus powered The USB interface must sup port a current of 500mA High Powered Interface The da...

Page 15: ...ID B docx 3 4 Antenna ports There can be 2 antennas connected to the ID ISC MU02 02 at the antenna ports ANT1 and ANT2 Figure 5 shows the position of the Hirose U FL receptacles with an input impedan...

Page 16: ...to control all 3 LEDs directly using an additional software protocol Table 10 shows the standard setting for the LEDs Table 10 Standard setting for the LEDs LED Color Standard setting V1 Red Flashes 5...

Page 17: ...e electromagnetic field due to reflections This will in turn result in reading holes and overshoots The distance between the antennas and a metal surface should be at least 5 cm Note that even other c...

Page 18: ...AL DATA Power Supply 5 V DC 5 Power Consumption max 2 W Operating Frequency 860 MHz to 960 MHz RF Power max 170 mW configurable Antenna Connection 2 x Hirose U FL receptacles 50 internal Multiplexer I...

Page 19: ...25 C to 85 C 13 F to 185 F Humidity 5 to 95 non condensing APPLICABLE STANDARDS Radio Regulation Europe USA Canada EN 302 208 FCC 47 CFR Part 15 IC RSS Gen RSS 210 EMC EN 301 489 Safety EN 60950 Cauti...

Page 20: ...G ELECTRONIC GmbH declares that the radio equipment type ID CPR74 is in com pliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet a...

Page 21: ...rt 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses...

Page 22: ...umber if Category II has been approved by Industry Canada to operate with the antenna types listed below with maxi mum permission gain and required antenna impedance for each antenna type indicated An...

Reviews: