9.9. [0x72] Set Output
The command Set Output serves temporary limited or unlimited activation of the outputs of the Reader.
Each output takes on the state defined by the byte OUTx-mode for the period of time (OUT-TIME)
included in the protocol. The flashing frequency is defined by the byte OUTx-frq. Via this protocol
the outputs can be switched on or off for the indicated period of time. If the Reader receives a
command Set Output, all times that have been active until then are being overwritten by the new
times included in the protocol if they are
>
0.
Host
→
Reader
1
2
3
4
5
6
7
0x02
n
COM-ADR
[0x72]
Mode
OUT-N
8
9
10,11
n-1...n
OUT-NR
OUT-S
OUT-TIME
CRC16
Repeated OUT-N times
Host
←
Reader
1
2
3
4
5
6
7,8
0x02
n
COM-ADR
[0x71]
STATUS
CRC16
Mode:
0x01 (reserved)
OUT-N:
Defines the number of output records.
OUT-NR:
Defines the Type and the number of the output
Bit:
7
6
5
4
3
2
1
0
Function:
OUT-
type
OUT-Number
OUT-type:
b0
Digital Output
The following outputs are available:
– OUT-1: LED green
– OUT-2: LED blue
– OUT-3: LED red