background image

IDENTIFICATION Installation 

ID 

ISC.M02.M8

 

FEIG ELECTRONIC GmbH 

Page 16 of 16 

M02M8-IM-e_02.doc

 

The manufacturer is obliged to test the terminal device together with the reader module according 
to the national FCC requirements according to 47 CFR Part15 §209 and §225 

For this purpose the reader module must be set to normal operation, ScanMode. The Scan mode 
is switched with on by SW command: Transparent Command - ISO 14443A [ReqA] HEX: 02 00 0A 
FF 00 30 02 01 

The manufacturer is obliged to test the terminal device together

 with

 the reader module according 

to the national FCC requirements according to 47 CFR Part15 §209 and §225 For this purpose the 
reader module must be set to normal operation, ScanMode. The Scan mode is switched with on by 
SW command: Transparent Command - ISO 14443A [ReqA] HEX: 02 00 0A FF 00 30 02 01 

The manufacturer is obliged to test the terminal equipment 

without

 RF transmitter, according to 

the national FCC requirements according to 47 CFR Part 15 Subpart B. For this purpose, the HF 
transmitter of the reader module must be switched off. The HF transmitter is switched off by the 
SW command: Transparent Command - HF Off HEX: 02 00 0A FF 00 04 01 00 

 

FCC-/IC-NOTICE: To comply with FCC Part 15 Rules in the United States / with IC Radio Stand-
ards in Canada, the system must be professionally installed to ensure compliance with the Part 15 
certification / IC certification. It is the responsibility of the operator and professional installer to en-
sure that only certified systems are deployed in the United States / Canada. 

 

 

Summary of Contents for ID ISC.M02.M8

Page 1: ...INSTALLATION MANUAL final public B 2020 06 03 M02M8 IM e_02 doc ID ISC M02 M8...

Page 2: ...re always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect functio...

Page 3: ...Characteristics 5 2 2 Available module 5 2 3 Available Accessories 5 3 Installation and wiring 6 3 1 Dimensions 6 3 2 Wiring 7 3 2 1 Supply voltage 7 3 2 2 RS232 LVTTL Interface 3 3V 8 3 2 3 Connecti...

Page 4: ...tallation operation and maintenance procedures should only be carried out by qualified personnel Use of the device and its installation must be in accordance with national legal requirements and local...

Page 5: ...uitable for any application in which short read ranges and small reader dimensions are required The module has an integrated antenna multiplexer Up to 8 external antennas can be connected 2 2 Availabl...

Page 6: ...16 M02M8 IM e_02 doc 3 Installation and wiring 3 1 Dimensions Fig 1 shows the dimensions of the ID ISC M02 M8 Reader Module in mm 5 0 3 65 0 3 80 0 3 5 0 3 45 0 3 50 0 3 16 5 0 3 4 0 3 X9 4 2 0 1 2 5...

Page 7: ...t of the multipoint connector X9 Note A wrong polarity of the DC voltage will destroy the reader 3 2 1 Supply voltage The reader ID ISC M02 M8 has to supplied by a limited power supply e g NEC Class 2...

Page 8: ...TL interface should be kept as short as possible and must in any case not exceed 1 m The transmission parameters for the interface can be software configured Table 3 shows the standard parameters for...

Page 9: ...be no longer than 1 m The use of other cable length are possible after consulting the manufacturer The input impedance for the antenna must be calibrated to a value of 50 3 3 A not correct tuned ante...

Page 10: ...materials can have a diameter of 6mm Non conductive materials can have a diameter of up to 10mm The mounting orientation of the reader module is arbitrary The component side on the top is the preferr...

Page 11: ...ly is used 3 3 4 EMC effects from magnetic fields Since in this type of RFID Technology the communication between the reader and transponder takes place by modulation of a magnetic field alternating m...

Page 12: ...pe MTA 100 AMP Electrical Data Supply voltage 24V DC 10 Current draw max 100mA Power consumption max 2 Watt Operating frequency 13 56 MHz Transmitting power 200mW 1dB Antenna connection up to 8 extern...

Page 13: ...Temperature range Operation Storage 20 C to 70 C 4 F to 158 F 40 C to 85 C 40 F to 185 F Humidity 5 95 non condensing Applicable Norms Radio approval Europa EN 300 330 USA FCC 47 CFR Part 15 Kanada I...

Page 14: ...ELECTRONIC GmbH declares that the radio equipment type ID CPR60 is in com pliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet add...

Page 15: ...which case the user will be required to correct the interference at his own expense Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exp...

Page 16: ...be set to normal operation ScanMode The Scan mode is switched with on by SW command Transparent Command ISO 14443A ReqA HEX 02 00 0A FF 00 30 02 01 The manufacturer is obliged to test the terminal eq...