OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 113 of 193
H90202-7e-ID-B.docx
8.3. [0x8A] Read Configuration
The Read Configuration Protocol is defined to query the complete or parts of reader configura-
tion.This protocol is an extension of [0x80] Read Configuration and realizes many improvements:
1. several destinations are addressable
2. one or all configuration blocks can be read
3. the address range is up to 65535 configuration blocks for each destination
4. different configuration locations for each destination are addressable
5. protocol ignores read protected configuration blocks and returns only readable configuration
blocks
Host
→
Reader:
Byte
1
2 + 3
4
5
6
7
Contents
0x02
LENGTH
COM-ADR
[0x8A]
DEVICE
BANK
8
9 + 10
11
12 + 13
MODE
CFG-ADR
CFG-N
CRC16
Host
←
Reader
Byte
1
2+3
4
5
6
Contents
0x02
LENGTH
COM-ADR
[0x8A]
STATUS
7
8
9, 10
11...
2 byte
CFG-N
BLOCK-SIZE
CFG-ADR
CFG-DATA
CRC16
Repeated CFG-N times
DEVICE:
The DEVICE identifies the target controller inside the reader. The following devices are
acceptable:
DEVICE
Value
RF-Controller
0x02