![Feig Electronic ID ISC.LRM1002-E Integration Manual Download Page 6](http://html1.mh-extra.com/html/feig-electronic/id-isc-lrm1002-e/id-isc-lrm1002-e_integration-manual_3876366006.webp)
Identification
Integration Manual
ID ISC.LRM1002-E
FEIG ELECTRONIC GmbH
Page 6 from 23
M21110-3e-ID-B.docx
3
Installation and mounting
3.1 Mounting ID ISC.LRM1002-E
The Reader Module is designed for installation on a heat sink. Mounting is accomplished using the
4.5 mm holes located on the base plate (see: Figure 1).
120
110
ø 4,5 mm*
160
155
80
ø 4,5 mm*
ø 4,5 mm*
5
ø 4,5 mm
155
ø 4,5 mm
5
4
29
V3 V2 V1
V4
NO
NC
COM
TxD
RxD
GND
GND
V
IN
GND
V
IN
IN -
IN +
X1
X5
X4
X6
X11
X3
ANT1
Figure 1: Scale drawing oft the Reader module ID ISC.LRM1002-E with mounting plate