background image

 

 

INTEGRATION

 

 

 

final 

– public (B) 

2019-06-05 

– M21110-3e-ID-B.docx

 

 

 

ID ISC.LRM1002-E 

Long Range Reader Modul 

 

 

 

 

(English) 

Summary of Contents for ID ISC.LRM1002-E

Page 1: ...INTEGRATION final public B 2019 06 05 M21110 3e ID B docx ID ISC LRM1002 E Long Range Reader Modul English...

Page 2: ...ensuing from incorrect or incomplete information Since despite all our efforts errors may not be completely avoided we are always grateful for your useful tips The instructions given in this manual a...

Page 3: ...a connection 8 3 2 1 1 Connection of a ID ISC DAT Dynamic Antenna Tuning Board 9 3 2 2 Supply voltage 10 3 2 3 OptocouplerInputs X5 IN1 11 3 3 Relay X6 REL1 13 3 3 1 Output 24V X5 VIN GND 14 3 4 Inter...

Page 4: ...r automatically set parameters for a device or for an incorrect application of a device Repairs may only be undertaken by the manufacturer Installation operation and maintenance procedures should only...

Page 5: ...e data carriers so called Smart Labels using an operating frequency of 13 56 MHz For the operation it is necessary to connect a appropriate external antenna to the connector ANT1 2 2 Available Reader...

Page 6: ...ader Module is designed for installation on a heat sink Mounting is accomplished using the 4 5 mm holes located on the base plate see Figure 1 120 110 4 5 mm 160 155 80 4 5 mm 4 5 mm 5 4 5 mm 155 4 5...

Page 7: ...ossible The use of heat sink compound is recommended If the antenna is properly tuned and there is sufficient air convection along the mounting plate the ID ISC LRM1002 E can be operated without an ad...

Page 8: ...l cables between readers and antenna must have defined lengths For all antennas of the company FEIG ELECTRONICS GmbH and for all antennas which with the tuning boards e g ID ISC DAT ID ISC MAT b and I...

Page 9: ...DC voltage is required This DC voltage must be provided via a power splitter ID ISC ANT PS B or a antenna multiplexer ID ISC ANT MUX Figure 4 shows the DC supply of the ID ISC DAT with a power splitt...

Page 10: ...on Description X1 VIN Vcc supply voltage 24 V X1 GND Ground supply voltage Table 3 Pin outs for supply voltage on X1 GND VIN X1 X5 Figure 6 Position oft he connector X1 for the power supply Note Rever...

Page 11: ...GND VIN IN IN X5 Figure 7 Optocoupler pin outs on terminal X5 The optocoupler on terminal strips X5 is galvanically isolated from the Reader electronics and must therefore be powered externally The e...

Page 12: ...put LED for the optocoupler is internally connected to a series resistor of 3 74k and is limited to an input current of max 6mA Note The input is configured for a maximum input voltage of 24 V and an...

Page 13: ...may however be provided by the reader from connector X5 VIN and GND See Output 24V X5 VIN GND V4 NO NC COM X4 X6 Figure 10 Relay Outputs on terminal X6 Figure 11 External wiring of the relay output s...

Page 14: ...rnal circuitry of the digital inputs or relay The maximum current consumption must not exceed 1A GND VIN IN IN X5 Figure 12 Optional 24V external voltage supply Note For the dimensioning oft the power...

Page 15: ...S232 interface is connected on X4 The transmission parameters can be configured by means of software protocol TxD RxD GND X4 X6 Figure 13 RS232 interface pin outs on X4 Kurzzeichen Description TxD RS2...

Page 16: ...be used The Figure 16 and table shows the connection of connector X11 5pol type JST PH RM 2 mm vertical X2 Pin No 1 Shielding USB cable shielding 2 GND 3 USB D PLUS 4 USB D MINUS 5 VCC 5 V DC 5 Option...

Page 17: ...Standard The prerequisite for using TCP IP protocol is that each device has a unique address on the net work All Readers have a factory set IP address Network Address IP Adresse 192 168 10 10 Subnet M...

Page 18: ...PROM status Short flashing indicates errorless communication with a transponder on the RF interface Flashes alternately with V1 after a reset following a software update Flashes alternately with V1 in...

Page 19: ...IG ELECTRONIC GmbH declares that the radio equipment type ID ISC LRM1002 E is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following in...

Page 20: ...ergy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause...

Page 21: ...ing a gain greater than the maximum gain indicated for that type are strictly prohibited for use with this device Le pr sent metteur radio identifier le dispositif par son num ro de certification ou s...

Page 22: ...oise Ripple max 150 mV Power Consumption max 16 VA Operating Frequency 13 56 MHz Transmit Power 1W 5 W Modulation 14 Antenna Connection SMA Jack 50 SWR 1 3 DC Supply at Antenna Con nector 6 5 V max 20...

Page 23: ...Tag it ISO18000 3M3 Upgrade Code required Optical Indicators 4 LEDs for Operating Status Diagnostics Ambient Temperature Range Operating Storage 20 C to 55 C 4 F to 131 F 25 C to 85 C 13 F to 185 F H...