5 Connectors
Page 23 of 38
5.7 Connector X6 - Auxiliary
On connector X6 an electrically isolated opto-coupler digital output and a connector for an external buzzer
are provided. The opto-coupler digital output is controlled by software and can be used to control a parking
barrier for example. The external buzzer output provides an PWM signal in parallel to the internal buzzer and
can be used to connect a piezo speaker.
Pin
Label
Direction
Remark
1
5 V DC
O
2
External Buzzer
O
PWM Output / max. 24 V DC / 100 mA
3
Opto-Out-C
I
max. 24 V DC / 20 mA / Resistive Load
4
Opto-Out-E
O
Table 9: Pin Assignment Auxiliary Connector (X6)
Required Connector:
The fitting complement for this connector consists of a 4-pole plug type Molex Micro Fit and the appending
crimp contact.
Manufacturer Ordering Code:
•
Molex 43645-0400
Plug, 4-pole, grid dimension 3.0 mm, single row, Molex Micro Fit receptacle housing
•
Molex 43030-0001
Crimp contact, female, grid dimension 3.00 mm, AWG#20-24, Molex Micro Fit
NOTE:
The interface is designed for max. 3 m (9.8 ft) cable length.
Fig. 16: Connector X6
– AUX
Summary of Contents for cVEND PIN
Page 13: ...4 Mechanical Integration Page 11 of 38 Fig 6 cVEND PIN recommended front panel cut out ...
Page 15: ...4 Mechanical Integration Page 13 of 38 Fig 8 cVEND PIN dimensions rear view ...
Page 16: ...4 Mechanical Integration Page 14 of 38 Fig 9 cVEND PIN dimensions side view ...