6. OPERATION
Instructions for Use
WARNING:
Always observe the safety instructions and applicable regulations.
WARNING:
To reduce the risk of serious personal injury, turn the tool off and disconnect the tool
from power source before making any adjustments or removing/installing attachments or accessories. Be
sure the trigger switch is in the OFF position. An accidental start-up can cause injury.
6.1 ON/OFF SWITCH (FIG. K)
♦ The workpiece should not be in contact with the cutterhead when switching on. To turn it on, press the
green start button of switch 9 (Fig. K). The tool now works in continuous operation.
♦ Allow the motor to reach full speed before feeding the workpiece.
♦ Allow the blades to cut freely. Do not force.
♦ To switch off, press the red stop button of the switch (9).
WARNING:
Always turn off the tool when work is finished and before unplugging.
6.2 PUSH STICK (FIG.A)
Use only the push stick provided by the manufacturer.
♦ This push stick (11) provides sufficient distance of the hand from the blade.
♦ Never use a damaged or cut push stick. A damaged push stick may break causing your hand to slip into
the blade.
♦ If small workpieces are inserted by hand, there is an increased risk of injury. It’s recommended to use the
push-stick. Keep your hand at a safe distance from the blade.
Always keep the push stick in its store place when not in use.
6.3 OVERLOAD PROTECTOR/RESET BUTTON (FIG. K)
This planer is equipped with an overload protector/reset button (10) which will automatically “trip” and cause
the planer to shut down if the motor is overloaded due to continuous heavy cutting.
The planer overload protector can only be reset manually by the user after the planer has been allowed to
adequately cool. Allow 15
–30 minutes.
Should the overload protector “trip”:
♦ Turn switch off (O).
♦ Raise carriage and remove board.
♦ After 15–30 minutes, reset overload protector by pushing the reset button (10) beside switch. An
audible click will indicate the overload protector is reset. Once the button is reset, the tool may be started
13