background image

32 

 

16. WARRANTY EXCLUSIONS  

THE WARRANTY DOES NOT COVER: 

• 

Start-up and setting up of the product. 

• 

Damage resulting from normal wear and tear of the product. 

• 

Damage resulting from improper use of the product. 

• 

Damage resulting from assembly or start-up not in accordance with the user manual. 

• 

Breakdowns related to carburetion beyond 90 days and fouling of carburetors. 

• 

Periodic and standard maintenance events. 

• 

Actions of modification and dismantling that directly void the warranty. 

• 

Products whose original authentication marking (brand, serial number) has been degraded, 

altered or withdrawn. 
• 

Replacement of consumables. 

• 

The use of non-original parts. 

• 

Breakage of parts following impacts or projections. 

• 

Accessories breakdowns. 

• 

Defects and their consequences linked to any external cause. 

• 

Loss of components and loss due to insufficient screwing. 

• 

Cutting components and any damage related to the loosening of parts. 

• 

Overload or overheating. 

• 

Poor power supply quality: faulty voltage, voltage error, etc. 

• 

Damages resulting from the deprivation of enjoyment of the product during the time necessary 

for repairs and more generally the costs related to the immobilization of the product. 
• 

The costs of a second opinion established by a third party following an estimate by a SWAP-

Europe repair station 
• 

The use of a product which would show a defect or a breakage which was not the subject of an 

immediate report and/or repair with the services of SWAP-Europe. 
• 

Deterioration linked to transport and storage

*

• 

Launchers beyond 90 days. 

• 

Oil, petrol, grease. 

• 

Damages related to the use of non-compliant fuels or lubricants. 

 

In accordance with transport legislation, damage related to transport must be declared to carriers 

within 48 hours maximum after observation by registered letter with acknowledgement of receipt. 
This document is a supplement to your notice, a non-exhaustive list. 

Attention: 

all orders must be checked in the presence of the delivery person. In case of refusal by 

the delivery person, it you must simply refuse the delivery and notify your refusal. 

Reminder: 

the reserves do not exclude the notification by registered letter with acknowledgement 

within 72 hours. 

Information: 

Thermal devices must be wintered each season (service available on the SWAP-Europe site). 
Batteries must be charged before being stored. 

 

 
 
 
 
 
 

Summary of Contents for FG8500RS

Page 1: ...ORIGINAL INSTRUCTIONS EN GASOLINE GENERATOR FG8500RS FG8500ES INSTRUCTION MANUAL CAUTION Read the instructions before using the machine...

Page 2: ...12 5 GENERATOR USE 14 6 PRE OPERATION CHECK 17 7 STARTING STOPPING THE ENGINE 19 8 MAINTENANCE 19 9 TRANSPORTING AND STORAGE 22 10 TROUBLESHOOTING 24 11 WIRING DIAGRAM 26 12 SPECIFICATIONS 28 13 EC D...

Page 3: ...as it runs Use safety equipment Wear protective gear such as an anti dust mask non slip safety shoes a helmet or hearing protection Stay vigilant watch what you are doing and show good sense when you...

Page 4: ...ible and easily ignited Do not refuel during operation Do not refuel while smoking or near naked flames Do not spill fuel Some parts of the internal combustion engine are hot and may cause burns Pay a...

Page 5: ...arth wire Do not operate the generator in parallel with another generator If using electrical extensions make sure that they are sufficiently thick to transport the current and that they are used corr...

Page 6: ...not dispose of old appliances with domestic rubbish Add engine oil Guaranteed sound power level No naked flames WARNING Make sure there are no spills or fuel leaks Ground connection Stay away from the...

Page 7: ...dd engine oil before using 2 COMPONENT IDENTIFICATION NOTE Diagrams may vary according to the types This gasoline generator intended used for out door site where the power needed less than power show...

Page 8: ...8 FG8500RS panel and rating label FG8500ES panel and rating label...

Page 9: ...een replaced Using an incomplete or damaged product represents a hazard to people and property 3 Ensure that you have all the accessories and tools needed for assembly and operation 3 2 SCOPE OF THE D...

Page 10: ...e generator Assemble the axis and wheel on one side of the support Assemble the axis and wheel on other side of the support 3 4 FOOT PAD Keep the tool upside down Localise the two holes on the bracket...

Page 11: ...11 3 5HANDLE Press the button then rolling over the handle Screw the support with screws and nuts...

Page 12: ...witch and wait 10 seconds before trying to start again 4 2 RECOIL STARTER To start the engine pull the starter grip lightly until resistance is felt then pull briskly NOTICE Do not allow the starter t...

Page 13: ...tch the generator power ON or OFF 4 6 GROUND TERMINAL The generator ground terminal is connected to the panel of the generator the metal non current carrying parts of the generator and the ground term...

Page 14: ...ound is not connected to the AC neutral wire If the generator is tested by a receptacle tester it will not show the same ground circuit condition as for a home receptacle Special Requirements There ma...

Page 15: ...cuit breaker 5 5 DC OPERATION DC Terminals The DC terminals may ONLY be used for charging 12 volt automotive type batteries The terminals are colored red to identify the positive terminal and black to...

Page 16: ...y cable from the generator negative terminal 3 Disconnect the other end of the negative battery cable from the battery negative terminal 4 Disconnect the positive battery cable from the generator posi...

Page 17: ...dipstick clean 2 Check the oil level by inserting the dipstick into the filler neck without screwing it in 3 If the level is low add the recommended oil to the upper mark on the dipstick 6 2 FUEL RECO...

Page 18: ...to help meet clean air standards If you use an oxygenated fuel be sure its pump octane rating is 86 or higher Ethanol ethyl or grain alcohol Gasoline containing more than 10 ethanol by volume may caus...

Page 19: ...d be recharged 1 When the engine starts allow the engine switch to return to the ON position 2 Turn the choke lever or push the choke rod to the OPEN position as the engine warms up 7 2 STOPPING THE E...

Page 20: ...ion or use it in unusually wet or dusty conditions consult your servicing dealer for recommendations applicable to your individual needs and use 8 2 TOOL KIT The tools supplied with the generator will...

Page 21: ...flash point solvent Allow the element to dry thoroughly 3 Soak the element in clean engine oil and squeeze out the excess oil The engine will smoke during initial start up it too much oil is left in...

Page 22: ...gine cool before transporting or storing the generator Take care not to drop or strike the generator when transporting Do not place heavy objects on the generator Before storing the unit for an extend...

Page 23: ...several revolutions to distribute the oil then reinstall the spark plug 4 Slowly pull the starter grip until resistance is felt At this point the piston is coming up on its compression stroke and both...

Page 24: ...gnite To check 1 Remove the spark plug cap and clean any dirt from around the spark plug 2 Remove the spark plug and install the spark plug in the plug cap 3 Set the plug side electrode on the cylinde...

Page 25: ...circuit breaker ON Check the electrical appliance or equipment for any defects YES NO Take the generator to an authorized generator dealer NO DEFECTS Replace the electrical appliance or equipment Tak...

Page 26: ...26 11 CIRCUIT DIAGRAM...

Page 27: ...27...

Page 28: ...920g kW h Lube Oil capacity L 1 1 L Sound pressure level LpA 72 3 dB A K 2 80 dB A Measured sound power level LwA 92 0 dB A K 2 80 dB A Guaranteed sound power level 95 dB A Generator SET AC out put Vo...

Page 29: ...designated below Gasoline Generator Model FG8500RS FG8500ES Serial number 20221111977 20221112106 20221112114 20221112251 Complies with the provisions of the Directive machinery 2006 42 CE and nation...

Page 30: ...ibed in the user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifications without notice Consequently the product may be different from the inf...

Page 31: ...t is available before dropping off the machine Go to the repair station with the complete machine packed accompanied by the purchase invoice and the station support sheet downloadable after the servic...

Page 32: ...oduct during the time necessary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate b...

Page 33: ...BUILDER SAS 32 rue Aristide Berg s ZI 31270 Cugnaux France Made in PRC 2022...

Reviews: