Ethanol (ethyl or grain alcohol)

Gasoline containing more than 10% ethanol by volume may cause starting or performance

problems. Gasoline containing ethanol may be marketed under the name “Gasohol".

Methanol (methyl or wood alcohol)

Gasoline containing methanol must contain cosolvents and corrosion inhibitors to protect the fuel

system. Gasoline containing more than 5% methanol by volume may cause starting and/or

performance problems and may damage metal, rubber and plastic parts of your fuel system.

MTBE (methyl tertiary butyl ether)

You may use gasoline containing up to 15% MTBE by volume. Before using an oxygenated fuel,

try to confirm the fuel’s contents. Some states (provinces in Canada) require this information to be

posted on the pump. If you notice any undesirable operating symptoms, switch to a conventional

unleaded gasoline. Fuel system damage or performance problems resulting from the use of an

oxygenated fuel are not ours responsibility and are not covered under warranty.

NOTICE

Oxygenated fuels can damage paint and plastic. Be careful not to spill fuel when filling your

fuel tank. Damage caused by spilled fuel is not covered under warranty.

6. STARTING/STOPPING THE ENGINE

Starting the engine

1. Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start

if a load is connected.

2. Turn the fuel valve to the ON position.

3. Turn the choke lever or to the CLOSE position, or pull the choke rod out to the CLOSE position.

4. Start the engine

• With recoil starter:

Turn the engine switch to the ON position.

Pull the starter grip until compression is felt, then pull briskly.

Summary of Contents for FG7000RE

Page 1: ...AL INSTRUCTIONS EN Gasoline Generator Instruction Manual Model FG7000RE Feider France 32 rue Aristide Berg s ZI 31270 Cugnaux France Made in PRC Warning Please read the manual carefully before using t...

Page 2: ...AC Applications 4 AC Operation 5 DC Operation 6 High Altitude Operation 5 PRE OPERATION CHECK 1 Engine Oil 2 Fuel Recommendation 6 STARTING STOPPING THE ENGINE 7 MAINTENANCE 1 Maintenance Schedule 2...

Page 3: ...Local regulations may impose restrictions on the age of the user Please do not use this device when people especially children or pets are nearby Direct them away from the working area The operator or...

Page 4: ...of the generator must be carried out by a qualified technician from an authorized after sales service center Use fuels that evaporate easily as starting aids if used properly Warning when you start th...

Page 5: ...d up to their rated power under the rated ambient conditions Prior to commencing maintenance work it shall be ensured that untimely start up is not possible Security measures when filling the fuel tan...

Page 6: ...erator with wet hands Do not run the generator under rain or snow Do not run the generator near water Connect the generator to earth Use a sufficiently thick conductor for the earth wire Do not operat...

Page 7: ...and let it cool completely A damaged silencer increases noise Do not throw motor oil into the drains but deposit it at a collection point set up for that purpose The fuel for this machine is combusti...

Page 8: ...sed room because exhaust emissions can lead humans or animals to coma to death This symbol indicates the surface is very hot and not touching Keep away from the machine Exhaust emissions are harmful t...

Page 9: ...oved inserted ON To run the engine after starting START To start the engine by turning the starter motor With Electric Starter Without Electric Starter Circuit breaker Voltmeter AC socket Oil filter c...

Page 10: ...er to snap back against the engine Return it gently to prevent damage to the starter 3 Fuel Valve The fuel valve is located between the fuel tank and carburetor When the valve lever is in the ON posit...

Page 11: ...Oil Alert System The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe limit t...

Page 12: ...egulations local codes or ordinances that apply to the intended use of the generator Please consult a qualified electrician electrical inspector or the local agency having jurisdiction In some areas g...

Page 13: ...ceed the current limit specified for any one receptacle If an overloaded circuit causes the AC circuit breaker to switch OFF reduce the electrical load on the circuit wait a few minutes and then reset...

Page 14: ...ded DC circuit will fuse the DC fuse if this happens replace fuse An overloaded DC circuit excessive current draw by the battery or a wiring problem will trip the DC circuit protector PUSH button exte...

Page 15: ...er main fuel jet in the carburetor and readjusting the pilot screw If you always operate the engine at altitudes higher than 5000 feet 1500 meters above sea level have an authorized generator dealer p...

Page 16: ...ed range 1 Remove the oil filler cap and wipe the dipstick clean 2 Check the oil level by inserting the dipstick into the filler neck without screwing it in 3 If the level is low add the recommended o...

Page 17: ...l tank Occasionally you may hear light spark knock or pinging metallic rapping noise while operating under heavy loads This is no cause for concern If spark knock or pinging occurs at a steady engine...

Page 18: ...rmation to be posted on the pump If you notice any undesirable operating symptoms switch to a conventional unleaded gasoline Fuel system damage or performance problems resulting from the use of an oxy...

Page 19: ...or push the choke rod to the OPEN position as the engine warms up Stopping the engine In an emergency To stop the engine in an emergency move the engine switch to the OFF position In normal use 1 Turn...

Page 20: ...mechanically proficient 3 For professional commercial use long hours of operation to determine proper maintenance intervals WARNING Improper maintenance or failure to correct a problem before operatio...

Page 21: ...hough this is unlikely unless you handle used oil on a daily basis it is still advisable to thoroughly wash your hands with soap and water as soon as possible after handling used oil Please dispose of...

Page 22: ...aner cover clips remove the air cleaner cover and remove the element 2 Wash the element in a solution of household detergent and warm water then rinse thoroughly or wash in nonflammable or high flash...

Page 23: ...lug Service Recommended spark plugs F5T or F6TC or F7TJC or other equivalents To ensure proper engine operation the spark plug must be properly gapped and free of deposits If the engine has been runni...

Page 24: ...spark plugs which have an improper heat range Use only the recommended spark plugs or equivalent 8 TRANSPORTING STORAGE When transporting the generator turn the engine switch and the fuel valve OFF Ke...

Page 25: ...and fill with fresh gasoline before starting Use gasoline conditioners that are formulated to extend storage life Contact your authorized generator dealer for conditioner recommendations 1 Drain the...

Page 26: ...t it from internal corrosion Align the notch on the starter pulley with the hole at the top of recoil starter The disassembled or damaged machine must be transferred to the professional organ for proc...

Page 27: ...nite To check 1 Remove the spark plug cap and clean any dirt from around the spark plug 2 Remove the spark plug and install the spark plug in the plug cap 3 Set the plug side electrode on the cylinder...

Page 28: ...e AC circuit breaker ON Check the electrical appliance or equipment for any defects YES NO Take the generator to an authorized generator dealer NO Replace the electrical appliance or equipment Take th...

Page 29: ...29 10 CIRCUIT DIAGRAM...

Page 30: ...power PRP 6 0kW AC max output power 6 5 kW Max Power factor 1 0 Rated output 25A Performance class G1 Quality class B Max temperature 40o C Max altitude 1000m Protection class IP23M DC output 12V 8 3A...

Page 31: ...31 Labels affixed on the machine...

Page 32: ...wing technical provisions EN 55012 2007 A1 2009 EN 61000 6 1 2007 Notified body of noise certificate ISET S r l Via Donatori del Sangue 9 46024 Moglia MN Italy NB 0865 Responsible for the technical fi...

Page 33: ...user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifications without notice Consequently the product may be different from the information co...

Page 34: ...fore dropping off the machine Go to the repair station with the complete machine packed accompanied by the purchase invoice and the station support sheet downloadable after the service request is comp...

Page 35: ...ssary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair sta...

Reviews: