background image

22 

 

 

 
 

 
 
 
 
 
5) Fuel Sediment Cup Cleaning 

 
The sediment cup prevents dirt or water which may be in 
the fuel tank from entering the carburetor. If the engine 
has not been run for a long time, the sediment cup should 
be cleaned. 
 
1) Turn the fuel valve to the OFF position. Remove the 
sediment cup, and O-ring. 
 
2) Clean the sediment cup, and O-ring, in nonflammable 
or high flash point solvent. 
 
3) Reinstall O-ring, and sediment cup. 
 
4) Turn the fuel valve ON and check for leaks. 
 

 

 

6) Spark Plug Service 

 

Recommended spark plugs: F5T or F6TC or F7TJC or other equivalents 

 
To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. 
 
If the engine has been running, the muffler will be very hot. Be careful not to touch the muffler. 
 
1) Remove the spark plug cap. 
 
2) Clean any dirt from around the spark plug base. 
 
3) Use the wrench supplied in the tool kit to remove the spark plug. 
 

Summary of Contents for FG3000-1

Page 1: ...NAL INSTRUCTION EN Gasoline Generator Instruction Manual Model FG3000 1 Feider France 32 rue Aristide Berg s ZI 31270 Cugnaux France Made in PRC Warning Please read the manual carefully before using t...

Page 2: ...rical System 2 Ground System 3 AC Applications 4 AC Operation 5 DC Operation 6 High Altitude Operation 5 PRE OPERATION CHECK 1 Engine Oil 2 Fuel Recommendation 6 STARTING STOPPING THE ENGINE 7 MAINTEN...

Page 3: ...Local regulations may impose restrictions on the age of the user Please do not use this device when people especially children or pets are nearby Direct them away from the working area The operator or...

Page 4: ...fuel tank Maintenance and repair of the generator must be carried out by a qualified technician from an authorised after sales service centre Warning when you start the generator with the cord watch o...

Page 5: ...d up to their rated power under the rated ambient conditions Prior to commencing maintenance work it shall be ensured that untimely start up is not possible Security measures when filling the fuel tan...

Page 6: ...ly The connection of a generator used for auxiliary power to the electrical installation of a building must be performed by a qualified electrician and in conformity to the provisions of the applicabl...

Page 7: ...nvironmental requirements To dispose of residual fluids proceed as follows Close the fuel tap Drain fuel from the fuel tank Empty carburettor fuel Symbol explanation Attention Please read the manual c...

Page 8: ...e near the machine Do not connect with the electricity system Danger Electrical shock 2 COMPONENT IDENTIFICATION Circuit breaker Voltmeter AC socket Oil filter cap Wheels Recoil starter grip Air clean...

Page 9: ...a time If the engine fails to start release the switch and wait 10 seconds before operating the starter again 2 Recoil Starter To start the engine pull the starter grip lightly until resistance is fel...

Page 10: ...ed OFF automatically check that the appliance is working properly and does not exceed the rated load capacity of the circuit before switching the circuit breaker ON again The circuit breaker may be us...

Page 11: ...electrical current from the generator to feedback into the utility lines Such feedback may electrocute utility company workers or others who contact the lines during a power outage Consult the utilit...

Page 12: ...ly turn it off immediately Disconnect the appliance and determine whether the problem is the appliance or if the rated load capacity of the generator has been exceeded Make sure that the electrical ra...

Page 13: ...tery positive to generator red terminal and battery negative to the generator black terminal With DC Circuit Protector With DC Fuse DC Circuit Protector or DC Fuse The DC circuit protector or DC Fuse...

Page 14: ...t If this happens wait a few minutes before pushing in the circuit protector to resume operation If the circuit protector continues to go OFF discontinue charging and see your authorized generator dea...

Page 15: ...ce performance and may over heat and seriously damage the engine 5 PRE OPERATION CHECK 1 Engine oil NOTICE Engine oil is a major factor affecting engine performance and service life Non detergent and...

Page 16: ...e is refueled or where gasoline is stored Do not overfill the fuel tank there should be no fuel in the filler neck After refueling make sure the tank cap is closed properly and securely Be careful not...

Page 17: ...l be sure its pump octane rating is 86 or higher Ethanol ethyl or grain alcohol Gasoline containing more than 10 ethanol by volume may cause starting or performance problems Gasoline containing ethano...

Page 18: ...ot allow the starter grip to snap back against the engine Return it gently to prevent damage to the starter or housing With electric starter Optional kit Turn the engine switch to the START position a...

Page 19: ...intervals shown in the Maintenance schedule below 1 MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD Performed at every indicated month or operating hour interval whichever comes first Each use First mont...

Page 20: ...wet or dusty conditions consult your servicing dealer for recommendations applicable to your individual needs and use 2 Tool kit The tools supplied with the generator will help you to perform the owne...

Page 21: ...arburetor malfunction service the air cleaner regularly Service more frequently when operating the generator in extremely dusty areas WARNING Using gasoline or flammable solvent to clean the filter el...

Page 22: ...mable or high flash point solvent 3 Reinstall O ring and sediment cup 4 Turn the fuel valve ON and check for leaks 6 Spark Plug Service Recommended spark plugs F5T or F6TC or F7TJC or other equivalent...

Page 23: ...w spark plug tighten I 2 turn after the spark plug seats to compress the washer If reinstalling a used spark plug tighten I 8 1 4 turn after the spark plug seats to compress the washer NOTICE The spar...

Page 24: ...diment cup 1 year or more Fill with fresh gasoline and add gasoline conditioner Drain the carburetor float bowl Drain the fuel sediment cup Remove the spark plug Put a tablespoon of engine oil into th...

Page 25: ...ce is felt At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protect it from internal c...

Page 26: ...nite To check 1 Remove the spark plug cap and clean any dirt from around the spark plug 2 Remove the spark plug and install the spark plug in the plug cap 3 Set the plug side electrode on the cylinder...

Page 27: ...circuit breaker ON Check the electrical appliance or equipment for any defects YES NO Take the generator to an authorized generator dealer NO DEFECTS Replace the electrical appliance or equipment Tak...

Page 28: ...28 10 CIRCUIT DIAGRAM...

Page 29: ...h Lube Oil capacity L 0 6 L Sound pressure level LpA 73 46 dB A K 1 72dB A Sound power level LwA 93 46 dB A K 1 72dB A Guaranteed sound power level 96 dB A Generator SET Generator set AC out put Volta...

Page 30: ...ersonnel i e free assembly by our technicians Provided that the damage is not due to improper use of the device To help you with your product we invite you to use this link or call us on 33 0 9 70 75...

Page 31: ...OHS Directive EU 2015 863 amending 2011 65 EU Emission directive EU 2016 1628 2017 656 EU Noise directive 2000 14 CE Annex VI 2005 88 CE Also complies with European standards with national standards a...

Reviews: