2) Exhaust oil. Remove the spark plug, pour a tablespoon of clean oil into the cylinder, pull the start handle a few
times to scatter the oil, and then install the spark plug back.
3)
Pull the handle slowly until it feels pressure. At this moment, the piston is rising to the top of its compression
stroke and the exhaust valve is closed. Storage in this case helps prevent rust inside the engine.
Troubleshooting
Cannot start the engine
有
是
是
NOTICE
If the generator cannot be started for the first time when the oil is added, or the oil is changed,
the oil alarm indicator flashes when pulling the start handle, at this time, the generator should be
shaken back and forth to ensure that the float of the oil alarm floats. If the generator still does
not start, please follow the troubleshooting instruction above.
NOTICE
Make sure no fuel spills around the spark plug. Spilled fuel may catch fire.
Check spark plug:
1. Remove the anode cap and clean the dirt around the spark plug.
2. Remove the spark plug and insert the spark plug into the anode cap.
3. Connect the spark plug side electrode with wire to the metal part of the engine to ground. (You can use the DC
output wire to replace the wire. Use one end of the clip to clamp the metal part of the engine, and the other end
connect to the side electrode of the spark plug.)
Is there any fuel in the tank
?
Is the start switch & oil switch on “ON”?
Does the engine has enough oil
?
Does the spark plug work
?
Refuel
Turn the switch to “ON” position
Add recommended oil
Replace
Return the generator to
an authorized dealer
for further assistant
Still not
working
否
否
No
Yes
Yes
Yes
No
Does the carburetor has enough gasoline
?
Check if the tubes are damaged
Yes
否
No
No
No