background image

1

2
3

4

5

6

4

1

5

2

3

6

Summary of Contents for PDGT701BE

Page 1: ...Commercial Dehumidifier www fehom com PDGT701BE Please read the manual carefully before using the unit USER MANUAL ...

Page 2: ......

Page 3: ... carefully to ensure proper use of the dehumidifier Our dehumidifiers are widely used in family bedrooms bathrooms basements offices and storage rooms etc It can be operated quickly and efficiently to reduce the room s humidity and bring you a healthy and comfortable life If there is any problems of the product please contact Fehom Customer Service at support fehom com with your Purchase Order ID ...

Page 4: ...d functions provided in this manual may not be the same as the actual product Please always refer to the actual product The model of the machine on the manual is for reference only Please operate the machine based on the actual product The right to interpret the relevant terms belongs to the company ...

Page 5: ...otes For your safety please read the manual carefully and keep the manual before you use the product for reference Please use this product according to the installation and operation instructions of this manual ...

Page 6: ...1 2 3 4 5 6 4 1 5 2 3 6 ...

Page 7: ...1 Understand the Control panel ...

Page 8: ...Down button to set the desired time setting range 01 24h can be cycled Press the button once again or no button operation for a few seconds the timing setting state will automatically be exited If the time is set to be 00 the time setting is invalid The humidity level can be set within a range of 10 RH to 98 RH in 1 increments When it starts work it will first automatically detect and show the roo...

Page 9: ......

Page 10: ...he room humidity is lower than the set humidity 2 When the setting value is read out to be lower than the room humidity the digital number will remain illuminated When the fan delays to start running indicator will be flashing it will light up when the fan is running RUNNING ...

Page 11: ... and unplug it 2 Find the gravity drain outlet at the bottom of the dehumidifier and connect the emergency hose to drain 3 After emptying the reser voir close the gravity drain outlet 4 Connect the pump drain hose Re plug and start the dehumidifier to check the pump function EC ...

Page 12: ...t will flash or display the alarm in case there are multiple errors on the unit it will display the errors in turn When one of above malfunctions occurs the buzzer will alarm for a few seconds press any key during the alarm to release the alarm sound Fehom ...

Page 13: ...r making the screws correspond to the screw holes 2 Tighten all the four screws on the hands respectively the installation is finished Handle Screws Tighten all the four hand screws complete the installation Put the handle into the groove at the back of the dehumidifier making the 4 screws correspond to the screw hole ...

Page 14: ...e water can drain out safely Please ensure that no kinks or other obstructions will stop the water to flow NOTE Ensure that water which runs to outdoors does NOT create a slip hazard If you use a bucket or other container for water collection check it regularly to prevent overflows The drain hose for the water pump can drain up to 15ft vertically More than 15ft may cause water back up to the pump ...

Page 15: ...In power disconnected status tilt the dehumidifier as the figure shown pull out the rubber plug and put the dehumifier straight to drain the sewage in the water tank Rubber plug Inclination 45 ...

Page 16: ......

Page 17: ...ime to resolve issues that may happen with the unit The list includes most issues but not the results of defective unit crafts or materials in the unit If all the troubleshooting steps have been exhausted and isse is stilling occuring feel free to get in touch with Waykar Customer Service to get further assistance ...

Page 18: ...aking The filter is blocked The pump reservoir is not in place The pump is defective The pump reservoir gets dirty Clean the filter Place the pump reservoir at the correct position Replace the pump Clean the pump reservoir Noise The pump does not drain If the dehumidifier is still not working properly as expected and the troubleshooting steps or solutions above may not resolve the issues please un...

Page 19: ...Please clean the filter every two weeks do not use hot water above 104 gasoline or toluene ...

Page 20: ...a 1 7MPa MOISTURE REMOVAL 65 F 60 RH 50 Pints Day MOISTURE REMOVAL 80 60 RH MOISTURE REMOVAL 86 80 RH MOISTURE REMOVAL 95 90 RH 90 Pints Day 150 Pints Day 180 Pints Day MAXIMUM ALLOWABLE PRESSURE This product can expose you to chemicals including Styrene and its compounds which is known to the State of California to cause cancer and birth defects or other reproductive harm For more information ple...

Page 21: ... defect occured including those newly purchased and unused from Fehom or through an authorized reseller wholly or substantially or as a result of faulty manufacturing parts or workmanship during the Warranty Period The warranty does not apply if damage is caused by other factors including but without limitation of support com we will dedicate suggest Fehom fehom Order ...

Page 22: ...FAQs and more information please visit www fe hom com We are expecting to see our products fulfill your life and hear your voice Your satisfaction means a lot to us Please tag us if you share a snap on your social media Scan the QR Code for Live Chat ...

Reviews: