Feel

T

e

c

h

 

:     

  (WAVE=TRGL) 

  (WAVE=TRGL) 

:

    (WAVE=TRGL) 

6.

 

COUNTER: the value of counter is displayed on screen. Import pulse from EXTF input, 
Reset the count value by pressing the OK button. 

 

 

7.

 

EXT.FREQ  refers  to  outside  the  frequency  measurement  function  which  is  capable  of 
measuring the EXTF input signal frequency. 

 

 
8.

 

SAVE: current  frequency  value,  current  waveform  and  duty  cycle data  can  be  kept  in 
the  instrument's  internal  memory  for  up  to  10  different  combinations.  To  save  the 
setting to a specific memory  slot, user can turn the coding switch to change to number 
of memory slot in which setting will be saved, and press the OK button to save the data. 
Upon  successfully  completion  of  saving the data,  “OK”  is displayed  on the lower-right 
corner  of  the  screen.  Setting  saved  into  memory  slot  0  will  incur  such  setting  being 
loaded  from  restart  of  the  device.  M1  andM2  has  a  special  significance  for  those 
FY3000S series device which has SWEEP function, M1 refers to the starting frequency; 
M2  refers  to  the  stop  frequency.  If  SWEEP  function  is  required,  user  has  to  ensure 
validity of the value set for M1 and M2 where FM2> FM1.   

       

Set the storage location

     

(Storage  parameters  to  position  '0  'is  completed,  OK 

displays) 

9.

 

LOAD  is  used  to  read  parameters  from  current  storage  location,  the  operations  is 
similar to SAVE. Please refer to SAVE. 

10.

 

TIME is set to scan time setting range: 1 second to 99 seconds. 

Summary of Contents for FY30 Series

Page 1: ...u n c t i o n a r b i t r a r yw a v e f o r mg e n e r a t o ru s e rm a n u a l FeelTech F Y 3 0 x x SS e r i e s F u n c t i o n A r b i t r a r y W a v e f o r mG e n e r a t o r U s e rm a n u a...

Page 2: ...manner Lastly such device can also be used as industrial equipment supporting module for electronic engineering laboratory production lines and educational purpose T h ei n s t r u m e n th a st h ef...

Page 3: ...ngle wave linearity 98 0 01Hz 10kHz Square wave an increase of Fall Time 1 0 0 n s Square wave duty cycle range 1 99 u TTL Export Frequency range 0 01Hz 2MHz 3MHz 5MHz 8MHz 10MHz 12MHz Margin 3Vp p Fa...

Page 4: ...rsor to left or right indication position Using the OK button to switch the frequency display units Hz kHz and MHz To change the output frequency please turn the coding switch to increase or decrease...

Page 5: ...ion is listed below a SINE corresponds to sine wave b SQUR corresponds to square wave c TRGL corresponds to triangular wave d ARBI1 ARBI2 ARBI3 user defined arbitrary waveform e prec1 PREC2 PREC3 PREC...

Page 6: ...aussian white noise The main output waveform amplitude modulation waveform The main output waveform is FM waveform 5 DUTY presents for the duty cycle the coding switch is used to adjust the duty cycle...

Page 7: ...change to number of memory slot in which setting will be saved and press the OK button to save the data Upon successfully completion of saving the data OK is displayed on the lower right corner of th...

Page 8: ...ncy and scan time need to be saved before starting sweep function 12 TTL output can be synchronized to the same frequency output two differential TTL level 13 The amplitude adjustment potentiometer to...

Page 9: ...y other application unless there is a special purpose and authorized use Before installation use should refer to the instructions for use of the technical indicators Failure to comply could result in...

Reviews: