background image

1

Space size for using the chair

At least 30cm in front of  the leg.

13

14

Kind suggestion

The adjustment before massage

Caution

Environment

Check environment

Don’t use the chair in wet places liks near 
swimming pool , bath room to avoid lea-
kage or electric shock.

Don’t use under sunlight or near stove
or other heating place to avoid upho-
lstery deteriorated.

Please use chair in flat place to avoid
chair falling or noise or other unexpected
trouble.

Check places in front

Check the areas when back and leg extending,

make sure no people, pets or other things 
around. 

Check power cable, plug

At least 10cm from wall.

(1) Clean the dust on plug on time.
      (using dry cloth).
(2) No damage, re-do, bend, stretch, tie or
 press with heavy thing(especially can’t be
 pressed by the chair) on power cable.

Check

Check surroundings

When the backrest or legrest reclines or 
extends, please pay attention to:

(1) Check any person or things in every
      direction.
(2) Check the space size.

The adjustment before massage

How to move massage chair

Adjustment before massage

Caution

Don’t move chair when it’s working in case 
of accidents or damage

M

as

sa

ge

 op

era

tio

n

How to move

Bind the cables and put them in the seat to 
avoid damage when moving.
If you plump the chair, it may damage the inner 
parts of the chair may get damaged.
Don’t use the castor if the floor is wooden or 
other easy damaged material. It will need 2 
or more persons to lift the chair.

Make sure the power is off and the plug 
doesn't touch the floor(It’s better to 
let the chair in standing 
status to avoid theback 
crashing the floor)

Normally

Lift up the legrest to make the gravity fall on 
the castor. Then push chair to destination 
and set it down.

Please hold the footrest to move the 
chair as shown in the picture in case 
any scratches on the leatherette

Before adjustment

Right position: 

Your back 

cling to the chair back, the

head clings to the pillow.

Avoid for the massage head detecting your 

acupunctuer point postion not right,otherwise 

you won't get good massage.

When you feel the 
intensity isn’t strong
enough,take off the 
pillow or cushion.

Because the chair is heavy, it may ruin
your floor in long time setting. 
Please put a blanket or 
other soft things to
protect your floor.

The remote control 

gives "beep" sound after 

acupuncture point tracking detecting 

finished,when micro-adjustment is needed,

just press up/down key on the remote 

control.

M

as

sa

ge

 op

era

tio

n

Please make sure the 

massage head in the 

seat part before sitting 

on the chair.

 

To avoid injure caused by 

wrong position of the 

massage head

.

Acupuncture

 

point

 

track

 

detecting

 

confirm

If massage head can

'

t detect when 

acupuncture point position detecting, 

shoulder position was default to the 

middle position. 

Summary of Contents for RK7905S

Page 1: ...RK7905S Please read SAFETY INSTRUCTIONS carefully before using the chair User s Manual L Shape Massage Chair...

Page 2: ...blood circulation of blood capillary 9 The seat comes with gentle squeezing massage powered by air bags relaxing the stressed muscle and quickly eliminate tiredness 10 The legrest and foot parts can b...

Page 3: ...backrest leg rest up down or leg rest retraction extension from reclining position During operation if you have body abnormal please stop the operation and go to consult your physician Please do not t...

Page 4: ...on PU Unplug the power before cleaning the chair Unplug the power after using the chair Don t use the chair outdoor Keep the chair away from heat wet sharp things and corrosive inflammable explosive...

Page 5: ...ad pad Back seat cushion Controller bracket Right shoulder massage device Remote control Right armrest Legrest Footrest Power switch Power case Fuse holer Power cord socket Backrest Preparation Legres...

Page 6: ...2 23 1 1 24 25 Seat frame surface assembly 26 Right side of seat airbag assembly 27 28 Castor Seat support bar 1 1 1 2 2 29 1 30 Controller bracket 1 Mechanical components diagram NO Q ty Name Mechani...

Page 7: ...the legrest to the main body unscrew from hangers of legrest connect 3 air pipes on legrest with air tap on main body from left to right is grey brown and black pipe Connect power line with power sock...

Page 8: ...o the left side of the backrest right part onto the right side of the backrest Attach the shoulder part to the backrest side Match the shaft to the hole on the side panel of the backrest and match the...

Page 9: ...rts of the chair may get damaged Don t use the castor if the floor is wooden or other easy damaged material It will need 2 or more persons to lift the chair Make sure the power is off and the plug doe...

Page 10: ...In ON status press power switch button massage chair will turn off and return massage machine automatic reset to the seat part legrest stays in the lowest position backrest stays in the highest posit...

Page 11: ...g Language Stop Exit Position Intensity Overall Upper Lower Middle Low Middle High Air After press MENU button choose air pressure through navigation key Press OK button there are two kinds of air pre...

Page 12: ...osition Unplug the power plug from the socket 1 Before using pull up the pillow back cushion etc to check if the PU material is broken if there is damage please stop using unplug the chair and ask for...

Page 13: ...soft cloth into 3 5 neutral detergent solution squeeze it then clean the stain on the surface gently Wash cloth squeeze it and wipe with detergent General cleaning If leather is dirty Wipe with soft c...

Page 14: ...orking Remove the obstacles turn off the power to have the massager rest for over half an hour before next turn working Check if there are any obstacles the chair overloads for the sake of safety some...

Reviews: