WALL PREPARATION
• DO NOT mount the Towel Warmer without
providing structurally secure headers as shown.
• DO NOT mount the Towel Warmer directly to sheet
rock or any other non-structural surface.
• Use longer fasteners as required if the finished wall surface
prevents adequate mounting with the screws provided.
• Provide a clearance hole in the lower header as required
to route field wiring to the Towel Warmer wiring box.
If a single gang electric box has been roughed-in, install
cover plate PN103877. See part numbers below for decora-
tive finish information. DO NOT install the Towel Warmer
without these instructions.
Cover Plate Part Numbers & Decorative Finishes:
Polished Chrome 103877PC
Polished Brass
103877PB
Polished Nickel
103877PN
Pewter
103877P
Satin Nickel
103877SN
Polished Gold
103877PG
Satin Gold
103877SG
Antique Brass
103877AB
Oil Rubbed Bronze 103877ORB
IMPORTANT NOTE:
Towel Warmers may have small
dimensional variations and must be measured prior to
installation.
For Technical Service Assistance:
East Coast Tel: 1-800-767-8326
West Coast Tel: 1-800-727-8326
Lower Heade
r (Z)
Upper Header (Z)
Lower Header (Z)
Upper Header (Z)
Wiring Box
X
Y
Wiring
Box
Finished
wall surface
Finished
wall surface
Y
X
3
MOUNTING DIMENSIONS
(inches)
For illustrative purposes only
MODEL
X (min)
Y
Z (min)
header
header
header
size
horizontal
length
vertical
length
W 500
5
22
5
⁄
8
2 x 6
W 542
23
1
⁄
4
24
3
⁄
4
2 x 6
W 634
19
27
1
⁄
8
2 x 6
!
WARNING
!
CAUTION