Hinged Front Glass
The front glass hinges up for easy cleaning of the case interior. Pneumatic cylinders assist in
lifting the glass. The glass will hold open in any position.
The hinged glass mechanism will give years of reliable operation in normal usage. Service on
the lift mechanism is required if . . .
-The glass becomes difficult to open.
-The glass does not hold in the open position.
-The glass closes fast.
Consult the factory if service is required.
NOTE: Condensation will occur on the front and side glass if the room environment exceeds 75º
ambient and/or 55% relative humidity conditions.
Periodic Maintenance
Cleaning Condenser Coil
Disconnect power to unit.
Remove the rear grill and vacuum the front surface of the condenser coil.
This should be done every one to two months as necessary.
Market Deli Refrigerated Cases
Page 9
CAUTION
:
Operation of lift-up glass is to be done by trained store
personnel only. This case is not intended to be used as
a self-serve unit. Do not allow customers to operate lift-
up glass.