IMSS E3265
- 15 -
OPERATING INSTRUCTIONS
User Controls
Power Switch
The unit has a power switch that turns off power to the entire unit, including the
condensate evaporator and the lights. This switch is located behind a lift up panel
on the unit base.
Light Switch
The unit has a light switch that turns on and off the interior lights of unit. This
switch is located below the lift up panel on the unit base.
Electronic Control
This control is located behind a lift up panel on the unit base.
Using Electronic Temperature Control (Refrigerated Models Only)
DIGITAL DISPLAY
SET POINT ADJUST MODE
POWER TO CONTROL ON/OFF
AND SET POINT UP ADJUST
MANUAL DEFROST AND
SET POINT DOWN ADJUST
COMPRESSOR RUN
INDICATOR
DEFROST MODE INDICATOR
ALARM INDICATOR
Button Overview
Press and hold this button for 3 seconds to turn
system on (if off) or off (if on).
Also used to adjust set point when in set point
adjust mode
Press to enter set point adjust mode, confirm set
point changes, and mute alarms.
Press and hold this button for 3 seconds to initiate
a manual defrost (and cancel defrost if initiated), also
adjusts set point down when in set point adjust mode
POWER SWITCH
ELECTRONIC
CONTROL / DISPLAY
LIGHT SWITCH