Installation and Maintenance Instructions
6
Models VSLR1 and VSLR1-IPX
Replacing a Dome
The pod domes filter the LED lights and protect the LED and circuitry. If a dome is damaged, it must be
replaced.
Tool required:
T25 Torx driver
Removing a Dome
To remove a light assembly dome:
1.
Disconnect all power to the light assembly at the battery.
2.
See Figure 4. Use a T25 Torx driver to remove the #10-32 Torx shoulder screw.
3.
Carefully lift the dome from the back and rotate it to a vertical position to avoid damaging the pod
hook and pod base gasket.
4.
Inspect the gasket on the base of the pod to insure it is not torn, brittle, or damaged. Replace it, if
necessary.
Figure 4 Dome removal and replacement
HOOK IN POD BASE
HOOK IN DOME
POD BASE GASKET
DOME
POD BASE
SEE DETAIL
DOME
HOOK IN DOME
CENTERED IN
OPENING IN POD
CENTERED
POD BASE
SEE DETAIL
290A6603
#10-32 TORX SHOULDER SCREW