14
Specifications
UltraVoice Remote Interface (UVRI-B)
User Programs
The UVRI-B has the capacity to store functions for specific alerting configuration.
Functions can be used to activate relays for control of external devices and activation of
pre-recorded messages. See the Commander Software Manual and the Informer-IP Setup,
Program, and User Manual.
Status Monitoring
The UVRI-B provides system monitoring with automatic or manual reporting of system
operation and status. The following items are monitored:
• System operation
• Audio Output
• Input voltage
• Charger/battery status
• Intrusion
• Local activations
Specifications
Table 2 Electrical on the Control Board
AC Power (JP38)
102-132 Vac, 120 Vac nominal, -15%, +10%
< 150 mA Standby
< 2000 mA with amplifier at full power
204-264 Vac, 240 Vac nominal, -15%, +10%
< 100 mA Standby
< 1500 mA with amplifier at full power
Battery Input Voltage Range 11.0-14 Vdc, on at 12 Vdc, off at 11 Vdc
12 Vdc Input Current Draw
< 600 mA Standby
< 13 A with amplifier at full power
Battery Charge Current
1.5 or 4.0 A selectable
Battery Charge Float Voltage 13.6 V +/-2%
24 V Input Voltage Range
(optional)
20.0-28.0 Vdc
24 Vdc Input Current Draw
(optional)
< 400 mA Standby
< 7.0 A with 100 W siren load
Table 3 Electrical on the Amplifier Board
Operating Voltage/Current
From Control Board
Power Output
100 W Amplifier Output with addition of output transformer
28.3 V
rms
into 8 Ω load for 100 W
Frequency response
+/- 3 dB from 300-6.0 kHz at transformer output
THD
< 5% at transformer output
Hum and Noise
< -45 dB