A.!Ethernet!Board!Specifications!
!
Electrical!
10.4.1!!
Input!Voltage!!
10.5!–!95!VDC!
Current!Draw!
<150!mA
!
!
Serial!Port!
!
Serial!Port!Protocol!!!RS232C,!N,!8,!1!
!!!!!
!!baud!rate!!
!
!!configurable
!
!
Ethernet!Port!
!
Protocol!
IEEE!802.3,!10!!
!
Base9T!connection
!
!
600!Ohm!Audio!Output!Port!
!
Protection!
MOV!and!Transorb!!
!
surge!protection!
Impedance!!
600!ohms!!
Audio!Output!Level! Adjustable!from!0.30!to!3.00!V
p9p
,!
(917!dB!to!+2.7!dB)!into!600!Ohms!
!
*NOTE:!To!use!the!600!ohm!input!for!activation!receive!audio,!a!jumper!must!be!across!
pins!293!at!JP8.!JP8!is!located!on!the!main!controller!card.!Refer!to!section!‘600!Ohm!
Adjustment!Procedure!for!Communications’.
!
!
Connectors!
!
JP1!
600!Ohm!Audio!Output!Port!
!
Balanced!line!output!
!
JP2!
JTAG!Emulation!port!
!
JP3!
Audio!Output!Expanded!or!
!
Flat!Selection!Jumper!
Jumper!pins!1!&!2!for!flat!audio!output!
!
Jumper!pins!2!&!3!for!expanded!dynamic!range!audio!output!
!