background image

BLUE 18 AWG  

100 W (SSP2000B/SSP3000B)

200 W (SSP3000B ONLY)

BROWN              18 AWG 

SERIAL PORTS

10 8 6 4 2

9

5

7

3 1

AUX

2 3

3

4

4

5 6 7 8

1

11 1 1 1 1

2

2 3 4

AUX

PARK

INPUT

   

+12V

   

+

  P

RADIO

RING

SPKR

DO NOT EXCEED 5 AMPS

MAXIMUM ON HORN RING

CIRCUIT. SEE INSTALLATION 

INSTRUCTIONS

RADIO

RING

SPKR

RADIO

RING

SPKR

RADIO

RING

SPKR

SM

 

Quick Connect Guide:  SSP3000B/SSP2000B System Wiring Connections

25500152 REV. A0 1014

SERIAL PORTS: Connect  

up to two Federal Signal  

serially-controlled devices.

SPEAKERS: Two are 

connected in parallel  

and in phase (SSP3000B).
SSP2000B has only one 

speaker.

For details, see the "SmartSiren Platinum Series Installation, Maintenance, 

and Service Manual" (P/N 25500151) and the "Convergence Network 

Configuration Software Manual" (P/N 2562418).

MICROPHONE  

(P/N 258B577-03)

SM 

1

SM 

2

SM 

3

SM 

4

SM 

5

SM 

6

 

 

 

 

 

 

SM 

7

SM 

8

8-HEAD 
S

IGNAL

M

ASTER

6-HEAD
S

IGNAL

M

ASTER

S

M POWER OUT (20 A 

 

FUSE ON TOP OF SIREN)

11 12 13 14 1

2

3

4

AUX. RELAYS

INPUTS

WHITE

BROWN

GREEN

ORANGE

VIOLET

YEL

LOW

GR

AY

BLUE

WHT/RED

WHT/ORG

WHT/YEL

WHT/BLU

WHT/BRN

WHT/GRN

WHT/V

LT

WHT/G

R

Y

SM SM SM SM SM SM

1

2

3

4

5

6

20 AWG  

RED 18 A

WG

BLACK

AUX. RELAYS 11-14:

2

 

A solid-state relays

are 12

 

Vdc out only.

For these two connectors  

(P/N 1751541 and P/N 1751542-01)  

see the enlarged detail on the right.

 

 

 

 

RELAY CABLE ASSY. 

(P/N 1751541)

10

8

6

4

2

9

7

5

3

1

WHITE

BROWN

GREEN

BLUE

RED

ORANGE

YELLOW

VIOLET

GRAY

BLACK

18 AWG

AUX. RELAY 1–10: 

10 A solid-state relays 9/10  

can be configured as 12 Vdc 

out or ground out. Relays 1-8 

are 12 Vdc out. The SSP2000B 

has only relays 1-6 and 10.

INPUTS 1–2: 

Apply ground  

to activate.

INPUTS 3–4:  

Apply 12 Vdc  

to activate.

PARK INPUT (BLACK):  

Sends a signal to the siren 

amplifier that:
•  mutes all siren tones except 

Air Horn and Manual
OR

•  disables white flashing lights
when the vehicle transmission 

is shifted into park or neutral.

HORN RING: Enables the 

step-through selection of 

siren tones each time the 

horn ring is pressed while 

the control of the tone is 

transferred.

Back of SSP3000B Siren Amplifier / Relay Module

FS 

C

onvergenCe

™ 

NETWORK 

CONNECTIONS 

(to serially-

controlled devices)

ACTIVE-LOW INPUTS 1-4: 

Ground-activated. Can be 

programmed to activate with the 

control pad, installer-supplied 

switches (current capacity of 

100 mA each), or with the two-

position switches on the steering 

wheel of the Ford Police Interceptor.

RADIO: Rebroadcasts 

incoming radio messages 

through the siren speakers.

6-PIN CABLE ASSY.  

(P/N 17500307): 

See connector detail below.

BLACK

RED

INPUT 4 (BLUE)

INPUT 3 (PURPLE)

INPUT 2 (WHITE/YELLOW)

INPUT 1 (GRAY)

TO -GND

TO +12 V CONNECTION 

ACTIVATED BY IGNITION (OR 

TO +BAT IF THE IGNITION 

TIMER FUNCTION IS USED)

IGNITION INPUT (YELLOW)

IF THE IGNITION TIMER 

FUNCTION IS USED 

22 AWG

FS 

C

onvergenCe

 NETWORK CONNECTION 

CABLE, 25 FEET LONG (P/N 1751357-02)

ETHERNET  

CABLE ASSY.  

(P/N 1751532)  

CONTROL PAD CABLE  

ASSY. (P/N 17500308)

Computer for the 

software configuration  

of the siren system.

S

ignal

M

aSter

™, RELAY and INPUTS   

CABLE ASSY. (P/N 1751542-01)

+

Reviews: